Welcome to ECVERY
2012 New model! Multi-channel combustible and toxic gas alarm monitoring system
2012 New model! Multi-channel combustible and toxic gas alarm monitoring system
Supplier Info
[China Supplier]
Contact Person : Ms. Gui Teresa
Tel : 86-451-82380878
Fax : 86-451-82380879
Product Detail
Alarm monitor Multi channels & 2/3-wire system LED display concentration Two alarm points for each unit 999 alarm records

2012 New model! Multi-channel combustible and toxic gas alarm  monitoring system KB-2000N8 

Performance and features

1) Wall-mounted & multi-circuits alarm controller, available to connect with two-wire & three-wire gas detector

2) LED display concentration easy for watch

3) Can set two alarm points value seperately

4) 999 alarm memories

5) Time clock can running at backstage and make the screen more clear

6) Can receive any 4-20mA signal

 

Product introduction

KB-2000N8 combustible gas alarm controller is the new launched product designed according to the national standard. This alarm controller mainly applies for locations of oil field, chemical industry, medicine, city gas, pipeline of transmitting oil gas and transfer station etc where the combustible and toxic gas easy to leak.

KB-2000N8 controller applies digital technique for high integration and smart instrument and can connect 8 channels of (4-20)mA signal of gas detector. The signal from the on-site test by detector will be turn back to display on the screen of alarm controller and make real time processing to the signals of normal, alarm and fault. Besides, KB-2000N series combustible gas alarm controller has the functions of uploading signal of RS-485(Mod Bus RTU) output which can upload the real time monitor message of alarm controller to DCS system which must be the standard input interface of RS-485(Mod bus RTU)or other system or instrument that can receive RS-485(Mod bus RTU signal. The chip of alarm controller applies new type of single chip technique, which increases the RAM volume of single chip and make alarm controller response quickly when receiving the alarm signal; the screen of alarm controller is LED display and clear & beautiful; the dedicated clock guarantee its precious timing when alarm controller is power off.

KB-2000N8 combustible gas alarm controller can store alarm records for 999 at most. It can monitor 8 channels of(4-20)mA detectors at one time and display working, fault, time, current gas concentration, low alarm and high alarm, it also can give audible & visual signal when it is in fault and alarm status to warn the related personnel to handle this.

The signal collection, alarm control and alarm display are all controlled by computer. The dedicated clock chip in this system can realize the precise timing and save the alarm message for 100 records when interruption of power. All the information including time, concentration, alarm setting, time of alarm and historical records is showed by four digits nixie tube. It has the functions of self-checking, noise reduction and resetting etc.

Technical parameters:

Power supply            

AC220V;  50HZ

Input signal        

(4-20) mA or RS-485(Mod Bus RTU)

Output signal

RS-485(Mod Bus RTU)

Indicated precision

0.1%

Alarm setting

low concentration alarm(setting according the customers’ requirement, default/standard is 25%)

Alarm mode

audible & visual alarm

Alarm volume

More than 65dB

Channel of detection

8 channels

Power consumption

≤50W

Relay output

Contact output of 4 channels of programmable relay

Contact capacity

3A@220AC,3A@24DC

Alarm records

999 records

Adjustment mode

Press key

Display mode

LED Nixie tube

Operating temperature

(0~40)°C

Relative humidity

(10~96)%RH

Atmospheric pressure

(86~106)kPa

Max working current

2A

Order guide

Model

Installation mode

Channel of Detection

Input signal

Output of RS-485

KB-2000N8

Wall mounted installation

1-8 channels

4-20mA

YES

KB-2000N8S

Wall mounted installation

1-8  channels

4-20mA

YES

KB-2000BN8Z

Wall mounted installation

10 channels

4-20mA

YES

Standard configuration

key; keyboard key; user manual; certificate of quality; safe tube

2012 New model! Multi-channel combustible and toxic gas alarm monitoring system

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.