Ads by Google
No. | Test item | Criterion | |
1 | Voltage | Charging voltage | DC:57.6V CC/CV(3.6v*16) |
Balance voltage for single cell | 3.60 V±0.03V | ||
2 | Current | Balance current for single cell | 70±5mA |
Current consumption for single cell | ≤150μA | ||
Maximal continuous discharging current | 25A | ||
3 | Overcharge Protection | Over charge detection voltage | 3.90±0.025V |
Over charge detection delay time | 0.96S~1.4S | ||
Over charge release voltage | 3.80±0.025V | ||
4 | Over-discharge Protection | Over discharge detection voltage | 2.0±0.05V |
Over discharge detection delay time | 115~173mS | ||
Over discharge release voltage | 2.3±0.05V | ||
5 | Over Current Protection | Over current detection voltage | 0.62v |
Over current detection current | 100±5A(adjustable) | ||
Detection delay time | 7.2ms~11ms | ||
Release condition | Automatic Recovery | ||
6 | Short Protection | Detection condition | Exterior short circuit |
Detection delay time | 200-500us | ||
Release condition | Automatic Recovery | ||
7 | Resistance | Protection circuitry | ≤20mΩ |
8 | Temperature | Operating temperature range | -40+85 |
Storage temperature range | -40+125 | ||
9 | Size | L150*W75*T18(mm) |
Battery Protection Circuit Module For 51.2V LiFePO4 Battery Packs at 25A limited