IT has applied high pressure,large flow imported centrifugal water pumps for different sorts of molds.the agent spreads deeply into the mold so as to guarantee constant temperature. the pipes have all applied stainless steel material.the pipes are smooth,erosion-proof and durable.
in heating ,the temperature increase speed is rather high,its cooling ability is very strong ,it is high efficient and power-saving.temperature control has applied FID mode,temperature control is rather precise.<max.+/-0.3> rapid and reliable so as to guarantee stability of shaping production.main electrical parts are all imported so as to realize safety and stablity of the machine.delicate appearance design saves limited space,which makes it convenient to move and use.
model | MKS-1A | MKS-2A | MKS-3A | MKS-4A | MKS-5A | MKS-6A |
temperature range | general temperature-90 | general temperature-90 | general temperature-120 | general temperature-120 | general temperature 120 | general tempertaure120 |
temperature method | PID | PID | PID | PID | PID | PID |
power | 380V50HZ | 380V50HZ | 380V50HZ | 380V50HZ | 380V50HZ | 380V50HZ |
heat transfer medium | water | water | water | water | water | water |
cooling method | direct cooling | direct cooling | direct cooling | direct cooling | direct cooling | direct cooling |
heating power | 3 | 6 | 6 | 12 | 20 | 32 |
pump | 58 | 58 | 66 | 100 | 120 | 200 |
motor | 0.55 | 0.75 | 1.1 | 1.1 | 1.5 | 2.2 |
pump pressure | 2 | 2 | 2.5 | 3 | 3 | 4 |
cooling water pipe | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1 |
recycled water pipe | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 |
dimension | 640*310*640 | 640*310*640 | 640*310*740 | 800*350*740 | 800*400*800 | 800*400*900 |
weight | 45 | 60 | 70 | 75 | 100 | 110 |
model | MKR-1 | MKR-2 | MKR-3 | MKR-4 | MKR-5 | MKR-6 |
temperature range | 45-160 | 45-160 | 45-160 | 45-250 | 45-250 | 45-250 |
temperature method | PID | PID | PID | PID | PID | PID |
power | 380V50HZ | 380V50HZ | 380V50HZ | 380V50HZ | 380V50HZ | 380V50HZ |
heat transfer medium | thermal conductivity of oil | thermal conductivity of oil | thermal conductivity of oil | thermal conductivity of oil | thermal conductivity of oil | thermal conductivity of oil |
cooling method | indirect cooling | indirect cooling | indirect cooling | indirect co oling | indirect cooling | indirect cooling |
heating power | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 2 |
pump | 3 | 6 | 9 | 12 | 20 | 32 |
motor | 30 | 30 | 60 | 100 | 140 | 200 |
pump pressure | 2 | 2 | 2.5 | 3 | 3 | 4 |
cooling water pipe | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 |
recycled water pipe | 1/2 | 3/4 | 3/4 | 1 | 1 | 1 |
dimension | 640*310*640 | 700*310*640 | 770*350*700 | 800*350*740 | 1100*600*1300 | 1300*600*1300 |
weight | 45 | 60 | 70 | 90 | 110 | 120 |
MK series mold temperature controller