CP01 gas detector, designed for car park use and commercial use, is suitable for detecting combustible gas and toxic gas like CO, H2S etc.
Detection principle: Electrochemical gas sensor or catalytic gas sensorRange: 0-1000 PPM for CO?? 0-100% LEL for combustible gas420mA signal output is compatible with all 420mA control systemsRS485 compatibleProtection degree: IP65Working voltage: DC24V±25%Relay output of high-alarm and low-alarm
Brief introduction
CP01 is a newly developed fixed gas detector of Hanwei. With high-quality electrochemical/catalytic gas sensor and excellent craftwork, it has the advantages of good repeatability, disturbing-proof against temperature and humidity, long life-span and easily operation.
It can transfer the gas concentration in air into digital signal output through 4-20mA electric current signal. It is suitable for gas detection in car parking or industrial environment where toxic gas or combustible gas leaks.
2. Technical Data
Model | CP01-A | CP01-B |
Working principle | Electrochemical (toxic gas) or Catalytic (combustible gas) | Electrochemical (toxic gas) or Catalytic (combustible gas) |
Detecting gas | CO or CH4 | CO or CH4 |
Detecting range | CO: 01000ppm or CH4: 0100%LEL | CO: 01000ppm or CH4: 0100%LEL |
Resolution | CO: 1ppm or CH4: 1%LEL | CO: 1ppm or CH4: 1%LEL |
Low alarm level | CO: 35ppm or CH4: 20%LEL | CO: 35ppm or CH4: 20%LEL |
High alarm level | CO: 200ppm or CH4: 50%LEL | CO: 200ppm or CH4: 50%LEL |
Signal output | 420mA Low alarm relay output High alarm relay output | RS485 |
Cable | 1.5 mm2×3 field cable | 1.5 mm2×4 field cable |
Sampling method | Diffuse naturally | |
Response time | 60s | |
Power supply | DC24V±25% | |
Consumption | 2W/channel | |
Working condition | Tem.: 2050 Hum.: ≤95% | |
Protection grade | IP66 | |
Air pressure | 86kPa106kPa | |
Weight | ≤500g | |
Dimension | L×B×H mm:165×118×62 | |
Transmission distance | ≤1000m |