Photovoltaic (PV) grid inverter is the core equipment in the PV grid power station, whose reliability; efficiency and security
 Technical Data          PV inverterEA3KLPVEA4KLPVEA5KLPV
Input (DC)   
Max DC power 3200Wp4400Wp5500Wp
Max DC voltage520V520V520V
Start Voltage150V150V150V
Nominal DC voltage 360V360V360V
Max DC current 18A20A20A
Full-load MPP voltage range 180~420V210~420V260~420V
Number of MPP-Trackers111
MPPT efficiency (static)over 99%over 99%over 99%
Max input current19A20A20A
Insulation voltage Basic insulation 3000Vdc / 1 minBasic insulation 3000Vdc / 1 minBasic insulation 3000Vdc / 1 min
output (AC)   
Nominal AC power 3000W4000W5000W
Nominal AC voltage 230Vac230Vac230Vac
AC voltage range 180Vac~260Vac180Vac~260Vac180Vac~260Vac
Nominal AC current15A20A25A
Nominal frequency50Hz/60Hz50Hz/60Hz50Hz/60Hz
Frequency tolerance range47~51.5Hz / 57~61.5Hz47~51.5Hz / 57~61.5Hz47~51.5Hz / 57~61.5Hz
Distortion (THD%)below 3% (at norminal power)
Power factor (cos phi)over 0.99over 0.99over 0.99
Insulation voltage Basic insulation 3000Vdc / 1 min
Number of grid phases111
Efficiency 
Max efficency 97.3%97.3%97.3%
Euro efficiency 96.2%96.2%96.5%
General requirements 
Standby  consumption12W 12W 12W 
Night consumption0W0W0W
Topologytransformerlesstransformerlesstransformerless
Mean Time Between Failure (MTBF)40,000h40,000h40,000h
Standard warranty 20 years20 years20 years
Protection 
Reverse protection (Input)YesYesYes
Short-circuit protection (Input/Output)YesYesYes
Overload protection (Output)YesYesYes
Undervoltage / Overvoltage protection point (Grid)160Vac/276Vac160Vac/276Vac160Vac/276Vac
Undervoltage / Overvoltage protection point (DC)120V/550V120V/550V120V/550V
Underfrequency / Overfrequency protection point (Grid)52Hz/ 46.5Hz ; 62Hz/ 56.5Hz
Leakage current protectionDIN VDE 0126-1-1
Fault current protection
Anti-islanding protection
Standards & guidelines   
Certificates TUV ,CE , DIN VDE0126-1-1,comply with the DK5940
EMCEN61000-6-1,EN61000-1-2,EN61000-6-3 , EN61000-1-4 / Class B
Safety and regulatory IEC 62109-1 
Other   
Dimensions(L×H×W)420 mm ×550 mm ×200mm
Weight25kg25kg30kg
Acoustic Noise level50dB(A)50dB(A)50dB(A)
Operation temperature range -20°C~+60°C (>45°C derating)
Relative humidity0~90 %0~90 %0~90 %
Protection type compliant with EN 60529IP65IP65IP65
    
 
EA3K5LPV/EA5KLPV   
Outdoor grid-connected PV inverter   
    
Advantage feature:   
Home appliance small-sized PV station, could be used in series
Transformerless design, maximum transfer efficiency up to 97.3%(Europe efficiency 96.5%)
Single MPPT (with 3 groups, with flexible configuration and installation)
Outdoor waterproof design (IP65)   
Wide range of operating temperature: -25°C-+60°C,and in 50°C, it can keep the max power output
Multi-lingual LCD display which could be set at user’s willing
RS485 and USB communication port   
TUV CE certificate, comply with Germany VDE 0126-1-1 standard. Italy DK5940 certificate, Australia AS4777 certificate, CQC (including SUN certificate)