FZ(R)N21-12D AC high voltage vacuum load breaking switch1.excellent breaking ability 2.small size 3.long electric life

FZ(R)N21-12D AC high voltage vacuum load breaking switch

FZN21-12D/T630-20 series three poles alternating current vacuum load break switch-fuse protector combination. It has merit of excellent breaking ability, small size, long electric life, free of maintenance, can break rated current, overload current (FZN21-12D/T125-31.5 can break short circuit current) and prevent device from phase-default operation. The switch has an obvious visible isolate fracture to assemble earth switch and electric spring mechanism, thus can conduct remote control. 

Ambient condition

1 Ambient temperature: max +40°C min -15°C(conveyance under -30°C is allowed)

2 Altitude: ≤1000m

3 Relative humidity: daily average relative humidity: ≤95%; monthly average relative humidity≤90%; daily average saturated vapor pressure ≤2.2*10-3 MPa; monthly average value   ≤1.8*10-3 MPa

4 Earthquake intensity: ≤8 degree

5 The installation should be free from fire, explosion, severe vibration, chemical corrosion and serious pollution

Order instructionComplete model and order quantity of the productRated current, rated voltage, rated voltage of operation mechanismNeed panel, earth switch, fuse protector or not, what is the rated current and quantity of fuse protectorRequired accessory and quantityOther requirement please contact with us directly 

Main technical data

Main Technical Data

 

 

 

 

 

Type

 

FZN21-12D/T630-20

FZN21-12D/T125-31.5

Rated voltage                                                             

kv

12

Rated current                                                             

A

630

1250

Rated short-time power frequency withstand voltage(1 min)   

kv

Fructure of vacuum interrupter 30

Rated short-time power frequency withstand voltage (valid)  

kv

Interphase or to ground 42,fructure 48

Rated lighting impulse withstand voltage

kv

Interphase or to ground 75,fructure 85

Rated dynamic stability current (peak)

 kA 

50

 

4S thermostability current

kA

20

 

Rated breaking current of active load

A

630

 

Rated breaking current of close loop

A

630

 

Rated breaking current of cable charging current 

kA

10

 

Rated capacitor volume of breaking non-load

kv

3150

Rated breaking joint current

v

 

1250

Output of energy of collider

 

 

2~5

Interruption of rated current 

times

1000

Rated short circuit making current

kA

50

Rated dynamic stability current of earth switch

kA

50

2S dynamic stability current of earth switch

kA

20

Rated voltage of assist circuit

v

AC,DC220       AC,DC110

Mechanical life                                           

times

10000

Contact erosion limit of vacuum interrupter                                      

mm

2

Manual operation moment of force

Nm

>200