Welcome to ECVERY
Indoor AC high voltage load switch
Indoor AC high voltage load switch
Supplier Info
[China Supplier]
Contact Person : Ms. Shan Yuki
Tel : 86-571-88334228
Fax : 86-571-88334228
Product Detail
FN5-12 Series Indoor AC high voltage load switch FN5-12 indoor AC HV load switch-fuse combinations

FN5-12 Series Indoor AC high voltage load switch

Product Overview FN5-12 Series indoor High-voltage alternating current switch load applied to the exchange of 50Hz, 10kV network as breaking and closing load current by short-circuit current. With fuse switch and cut off the load short-circuit current for protection switching purposes. The CS Series switches equipped with a dedicated port or manual CS6-1-type manual operation agencies.

Features a, small size, light weight, simple structure, easy maintenance, operation of small force; b, a reliable mechanical interlock to prevent misoperation; C, clear visibility of the fracture; d, gas interrupter self-productive, stable performance, safe and reliable; E, there is lack of combination of electrical protection.

Technical parameters

Rated voltage 10 KVMaximum working voltage  12 KVRated frequency  50 HZRated Current 400A ,630 ARated current short-term tolerance (heat-stable current) 12.5 / 4, 20 / 2 KA/SRated peak current tolerance (dynamic stability of current) 31.5, 50 KARated breaking current of the closed-loop 400 ,630 ARated active load breaking current  400 ,630 A5% rated active load breaking current  20 ,31.5 ARated cable charging breaking current  10 ARated no-load transformer breaking current transformer no-load current 1250kVA Rated short-circuit closing current  31.5 ,50 KABreaking load current number of load / 100% / 20 30% / 75 60% / 35 5% / 80 1min power frequency withstand voltage (RMS) on the land, White / isolation fracture  42/48 KVFrequency tolerance voltage isolation between fracture 53 KVLightning Impulse Voltage tolerance (peak)-to-ground, White / isolation fracture  75/85 KVSub-switch operation of torque (force) N. m 90 (180) 100 (200)

 

FN5-10 load switch - fuse combinations of technical parameters

Rated voltage 10 KVMaximum working voltage 12 KVRated frequency  50 HZRated Current  100 ARated short-circuit breaking current (expected RMS)  40 KARated short-circuit closing current (expected rms)  100 KAA 1400 rated current transfer 1min power frequency tolerance voltage (RMS)-to-ground, white / isolation fracture  42/48 KVLightning Impulse Voltage tolerance (peak)-to-ground, white / isolation fracture  75/85KV Output energy impact fuse pieces of J 2 ~ 5

Order Information When ordering please specify: a, the load switch model, name, number; b, if the fuse please specify fuse with the rated voltage, rated current; C, the model with institutions.

Indoor AC high voltage load switch

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.