Technology parameter
1,Environmental requirement
Ambient temprature : -45°C~+80°C
Relative humidity:40°C, 20%~90%
2,the rate working voltage and current
Voltage:380V/220V three-phase
voltage synchronize changes not greater than ±20%
Frenquency:50Hz±5%
Current:100A
3,main technical
life:1 million times
phase number:three phase,single phase
control capacity:three phases com-up≤30Kvar
single phase supply≤10Kvar
the consumption of machine power ≤1.5VA
Contact Buck≤100mV
Contact Pressure≥1600V AC
Response time ≤20ms
Connected and turn off interval time≥300ms
The each of successive interval time≥10S
Height :≤3500M
Protection function
1.the protection of fault-phase voltage
2.the protection of power supply voltage
3. the protection of self-diagnosis the fault
4. the no-load protection
5.power outage protection
Insulation level: under the normal atmospheric≥10MΩ
Starting voltage:DC 10V~30V
impedance input:≥6.8KΩ
On-resistance:≤0.003Ω
Run indication
1.working light:after closing the switch , the lights , after swtich off , the lights go out.
2.Trouble lamp:failure, the lights, after repaired , the lightsgo out.
NFC-401 Mechatronics Integration Complex Switch