Product Detail
1.According to the BS 5467/IEC 60502-1 2.suitable to be laid in the power line of 0.6/1KV 3.PVC sheath power cable

1.Brief  Introduction 

For laying indoors , in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.

For laying indoors , in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.

2.Maximum working temperature 

The maximum operating temperature of conductor shall not exceed 90 . When the cable is used for long period. The temperature of conductor shall not exceed 250 at short ciruit for 5 seconds.

3.Installation of cables

The installation of cables is not limited by the difference of elevation along theeroute. The ambient temperatuture should not be below 0 during installation..The permissible bending radius for cable shall be complied with the regulationnas below::For single-core: R>25(D+d) +/- 5% For multi-core: R>15(D+d) +/- 5%%where: R-----bending radius (mm) D-----overall diameter of cbale (mm))  d-----diameter of conductor (mm)

4.Technical Specifications

    

                                              Cores and Nominal Cross Section Area:

1 core (mm2)2 core (mm2)3 core (mm2)3 core + 1 core (mm2)4 core (mm2)3 core+ 2 core (mm2)4 core + 1 core (mm2)5 core (mm2)
1×42×43×43×4+1×2.54×43×4+2×1.54×4+1×2.55×2.5
1×62×63×63×6+1×44×63×6+2×44×6+1×45×4
1×102×103×103×10+1×64×103×10+2×64×10+1×65×6
1×162×163×163×16+1×104×163×16+2×104×16+1×105×10
1×252×253×253×25+1×164×253×25+2×164×25+1×165×16
1×352×353×353×35+1×164×353×35+2×164×35+1×165×25
1×502×503×503×50+1×254×503×50+2×254×50+1×255×35
1×702×703×703×70+1×354×703×70+2×354×70+1×355×50
1×952×953×953×95+1×504×953×95+2×504×95+1×505×70
1×1202×1203×1203×120+1×704×1203×120+2×704×120+1×705×95
1×1502×1503×1503×150+1×704×1503×150+2×704×150+1×70 
1×1852×1853×1853×185+1×954×1853×185+2×954×185+1×95 
1×240 3×2403×240+1×1204×2403×240+2×1204×240+1×120 
1×300 3×3003×300+1×1504×3003×300+2×150  

Service Conditions And Parameters Of Cable:The maximum conductor operating temperature: 90°C;Short Circuit Temperature      250°CNot more than 5 secretaryEnvironmental Temperature of operatingIn air: 40°C,  Underground:  25°CDepth of laying in direct: 80cmThermal Resistance of soil: 1.2°C.cm/WEnvironment temperature should be no lower than 0°C for laying the cable.

 5.Certificates and honours

6.Welcome to our factory

 

7.Packing details

8.After-sale service

1. Free instruction for the installation of cables and wires.

2. Free information for the new kinds or revised cables and wires.

3. Free solutions about some daily maintenance.

4.Other related information about the cables,shipping details,freight, and other technique data for the customers'using.

5. Invitation for the business negotiation.

United Arab Emirates Market best seller XLPE insulation fire resistant electrical cable companies

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.