Welcome to ECVERY
Hign & Medium Voltage XLPE Power Cable for Rated Voltage up to 220KV
Hign & Medium Voltage XLPE Power Cable for Rated Voltage up to 220KV
Supplier Info
[China Supplier]
Contact Person : Ms. WANG NICOLE
Tel : 86-0734-8242052
Fax : 86-0734-8242052
Product Detail
Hign & Medium Voltage XLPE Power Cable for Rated Voltage up to 220KV

1.In order to reduce skin effect and improve transmission capability, the large section-area split conductor is elected.2.The VCV line is adopted to make extruded cores put into the culcanizing tube vertically. In order to settle insulation eccentric problem completely,the cores must be inspected by the insulation eccentric inspection appa ratus from Sikora in our company, and the line is all dry curing and tooting method.3.Triple-extruded technology, improved the electrical properties of cable highly, has be introduced in insulation, shield in and outside to make sure of smooth and compacted-connection border between those layers.4.To meet the requirements of longitudinal and radical water-proof and short circuit capability, expansive water-proof merial, corrugated aluminium and lead sheath is introduced. Its mechnical and water-proof properties are very well.5.In order to enssure the high purification of rare material strictly, extra- purification extra smooth imported materials as well as 1000-class purification room and all-tight input system are adopted in insulation and shield in and outside.6.Computer is adopted in VCV to select and control technical parameter to make sure of high control precision and automatic control degree.

 
Type,designation and application of extra-high voltage XLPE insulated power cable: 
TypeDesignationEnvironmentNorminal section area (mm2)
CopperAluminum
YJLW02YJLLW02XLPE insulated corrugated aluminum sheathed PVC sheathed power cableFor laying vertically burried or in tunnels,trenches,wells.There is no limitance in deference level240-2000240-8001000-2000
YJLW02-ZYJLLW02-ZXLPE insulated corrugated aluminum sheathed PVC sheathed longitudinal water-proof power cableFor laying vertically burried or in tunnels,trenches,wells.There is no limitance in deference level
YJLW03YJLLW03XLPE insulated corrugated aluminum sheathed PVC sheathed power cableUsed in condition with higher requirement to cable outer sheath.The laying environment is as above,but flame retardant measures must be considered when in tunnels wells240-2000240-8001000-2000
YJLW03-ZYJLLW03-ZXLPE insulated corrugated aluminum sheathed PVC sheathed longitudinal water-proof power cableThe requirements is as above,the product has properties of longitudinal water-proof
YJQ02YJLQ02XLPE insulated lead sheathed PVC sheathed power cableFor vertically burried or laying in tunnels240-2000240-8001000-2000
YJLW02-ZYJLLW02-ZXLPE insulated lead sheathed PVC sheathed longitudinal water-proof power cableThe requirements is as above,the product has properties of longitudinal water-proof
YJQ03YJLQ03XLPE insulated lead sheathed PE sheathed power cableUsed in condition with higher requirement to insulation of cable outer sheath.The laying environment is as above,but flame retardant measures must be considered when in tunnels wells240-2000240-8001000-2000
YJQ03-ZYJLQ03-ZXLPE insulated lead sheathed PE sheathed longitudinal water-proof power cableThe requirements is as above,the product has properties of longitudinal water-proof
Type,designation and the main application environment
TypeDesignationApplication
CopperAluminum
YJLV YJLY ZR-YJLVYJV YVY ZR-YJVXLPE insulated plastic sheathed lfame retardant or non-flame retardantUsed in indoors or outdoors,its enough to bear pulling tension,but isnt able to bear external machine force,single-core cables must not be laid in magnetic ducts
ZS-YJV ZS-YJYZS-YJLV ZS-YJYXLPE insulated plastic shiathed waterproof power cableUsed in indoors or outdoors,its enough to bear pulling tension,but isnt able to bear external machine force,single-core cables must not be laid in magnetic ducts,and may used in moisture or higher water level of ground.
YJV22 YJV23 ZR-YJV22YJLV22 YJLV23 ZR-YJLV22XLPE insulated steel-tape armoured plastic sheathed flame retardant or nonflame retardant power cable.Used in burial.Its able to bear external radical machine force, but isnt able to bear tension.
YJV32 YJV33 ZR-YJV32YJLV32 YJLV33 ZR-YJLV32XLPE insulated fine steel-wire armoured plastic sheathed flame retardant or nonflame retardant power cable.Used in water or have higher difference of level,its able to beal external machine force or certain tension.
YJV42 YJV43 ZR-YJV42YJV42 YJV43 ZR-YJLV42XLPE insulated coarse steel-wire armoured plastic sheathed flame retardant or nonflame retardant power cable.Used in water or have higher difference of level,its able to beal external machine force or much tension.
YJAYJLAXLPE insulated composed covered plastic sheathed power cable.Used in tunnel and duct. Its may be used in places such as moisture and higher water level of ground, but cant bear machine pressure and tension.
YJQ02 YJQ03YJLQ02 YJLQ03XLPE insulated lead-clapped plastic sheathed power cable.Used in tunnel and duct. Its may be used in places such as moisture and higher water level of ground, but cant bear machine pressure and tension.
YJLW02 YJLW03YJLLW02 YJLLW03XLPE insulated corrugated aluminum clapped plastic sheathed power cable.Used in tunnel and duct. Its may be used in places such as moisture and higher water level of ground, but cant bear tension,can bear a little pressure

Hign & Medium Voltage XLPE Power Cable for Rated Voltage up to 220KV

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.