19inch Rack Mount PDU Power Distribution Unit Box (YKDPZ-B)
19inch Rack Mount PDU Power Distribution Unit Box (YKDPZ-B)
Supplier Info
[China Supplier]
Contact Person : Ms. Gao Molly
Tel : 86-20-85558952
Fax : 86-20-85550802
Product Detail
19inch Rack Mount PDU Power Distribution Unit Box 1:In:2chs 48VDC 300A Fuse 2:Out:18chs 48VDC 3: 6/10/16/20/32/63/100A Option

  19inch Rack Mount PDU Power Distribution Unit Box 

 

Regards as 19inch Rack Mount PDU Power Distribution Unit Box, We can customized all kind of PDU according to your request 

Input 2chs -48VDC/24VDC/220VDC/110VDC or -48VAC/24VAC/220VAC/110VAC , with 10A, 16A, 32A, 63A ,100A,125A circuit breaker/air switch can be optionalOutput 1-20chs or 1-8chs can be optionalwith 10A, 16A, 32A, 63A,100A,125A  (optional) output current capacityWith alarm function or without alarm function.The max output Channel we can make is 36 channels.

YKDPZ-A is a DC power distribution system module with 19inch standard structure, small size , easy to install and use. There is A-B 2chs input, multi-channels output (max 18chs). Visual-aural alarm when there is failure. LED display running status

This equipment has excellent performance and reliable quality. It’s widely used in Telecom, BTS, Mobile, Unicom, electric power, army, public security, etc.

(YKDPZ-B) 19inch Rack Mount PDU Power Distribution Unit Box Technical specification

Item

Technical specification

Rated voltage

-48V

Insulation resistance

≥30MΩ

Insulating intensity

Input—housing AC1000V,50Hz,1minute

Output-housing AC1000V,50Hz,1minute

Input channels

2chs -48VDC 300A fuse

Output channels

Output 1-16chs with 6chs 63A, 6Chs 32A , 4chs 16A

Alarm

Visual-aural alarm signal. When there is any channel is failed,

Red LED ON and buzzer sounds.

Working environment

Working temperature 0°C~40°C

Related humility ≤90% (+20±5°C)

atmospheric pressure70Kpa~106Kpa

Dimension

44.8 mm *180 mm *245 mm   

Weight

12.0Kg

Packing:

540mm*340mm*220mm  

(YKDPZ-B) 20chs Rack Mount for Telecom PDU-Power Distribution Unit, pdu, 19inch Rack Mount PDU Power Distribution Unit Box Visual-Aural Alarm

This DC power distribution system module can display the running status of all the channels. When there is failure or break, Red LED ON and buzzer sounds and giving the alarming signal to third party system for alarming

If you want to stop alarm, please press “SA” button. If there are others failure right now, there will be no alarm.

When there is failure again, RED LED still ON, and it will not OFF until the failure is eliminated and switch is turn on

(YKDPZ-B) 19inch Rack Mount PDU Power Distribution Unit Box Installation and connection

1.       Install

Easy and simple install. Standard 3.0U structure, can install in the standard 19 inch cabinet.

2.       Connection

All the connection is on the rear panel.  

Please connect with the anode, cathode and grounding as required. Please tighten the connection screw and nut. Connection must be steady and reliable to reduce the resistance.

3.       Note

Please don’t change or replace any wiring or air switch etc inside the dc power distribution system module. If you want to change or replay, please contact with manufactures.

(YKDPZ-B) 20chs Rack Mount for Telecom PDU-Power Distribution Unit, pdu, pdu power distribution unit, power distribution unit

Notes

Must be engineer or technician or electrician to install the DC power distribution system !

Open the package, check the DC power distribution system module appearance and accessories is damaged or not in transportation.Check before electrify check the appearance, power wiring, terminal board also the screw is loosen / damaged or not.Check the INPUT DC power source is as requireMake sure the correct connection of anode “+” and cathode

Shipping and handing

DHL, Fedex, TNT, UPS and EMS By sea, by air are available.

Refund(Exchange Only)

1. If you are not satisfied with your purchase, you can exchange the items received. you must contact us within 3 days of the receipt of your order. And you should pay all additional shipping fees incurred and the items returned should be kept in their original status.

2. If you wish to exchange defective or incorrect shipped goods, please contact us within 3 days after receiving the goods.

Notes

1. The buyer are responsible for any insurance you think necessary.

2. The processing time for a specific order varies with the product type and stock status. Mostly, processing time can be 3 to 15 working days.

3. All items must be returned in their original condition, in order to qualify for a refund or exchange of goods.

4.Items returned after 7 days of delivery are only eligible for repair.

5. The buyer is responsible for all shipping costs incurred.

Feedback

1. Since your feedback is very important to our business's development, we sincerely invite you to leave positive feedback for us if you are satisfied with our product

19inch Rack Mount PDU Power Distribution Unit Box (YKDPZ-B)

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.