(YKDPZ-B) With high efficiency 18chs DC Distribution Cabinet system
(YKDPZ-B) With high efficiency 18chs DC Distribution Cabinet system
Supplier Info
[China Supplier]
Contact Person : Ms. Gao Molly
Tel : 86-20-85558952
Fax : 86-20-85550802
Product Detail
18chs DC Distribution Cabinet system 1.2chs 48VDC 100A input 2.Output 14 chs 63A, 2 chs 32A, 2 chs 20A current 3.Alarm

YKDPZ-B  18 channels PDU socket

2chs-48VDC 100A input

Output 14 channels 63A, 2 channels 32A, 2 channels 20A current capacity

Alarm function and giving the alarming signal to third party system for alarming 

high efficiency

Regards as PDU/ DC Distribution Box/ DC Power Distribution Cabinet/ DC Distribution Unit

We can customized all kind of PDU according to your request 

Input 2chs -48VDC/24VDC/220VDC/110VDC or -48VAC/24VAC/220VAC/110VAC , with 10A, 16A, 32A, 63A ,100A,125A circuit breaker/air switch can be optionalOutput 1-18chs or 1-8chs can be optional with 10A, 16A, 32A, 63A,100A,125A  (optional) output current capacity With alarm function or without alarm function.The max output Channel we can make is 36 channels.

(YKDPZ-B) 18chs DC Distribution Cabinet system/ Intelligent PDU system/ Telecom Power Distributing Cabinet Introduction.

YKDPZ-B is a DC power distribution system module with 19inch standard structure, small size , easy to install and use. There is A-B 2chs input, multi-channels output (max 18chs). Visual-aural alarm when there is failure. LED display running status

This equipment has excellent performance and reliable quality. It’s widely used in Telecom, BTS, Mobile, Unicom, electric power, army, public security, etc.

(YKDPZ-B) 18chs DC Distribution Cabinet system/ Intelligent PDU system/ Telecom Power Distributing Cabinet specification

Item

Technical specification

Rated voltage

-48V

Insulation resistance

≥30MΩ

Insulating intensity

Input—housing AC1000V,50Hz,1minute

Output-housing .  AC1000V,50Hz,1minute

Input channels

2 channels  DC-48V,100A

Output channels

18 channels

14 channels DC-48V,63A

2 channels DC-48V,32A

2 channels  DC-48V,20A

Alarm

Visual-aural alarm signal. When there is any channel is failed,

Red LED ON and buzzer sounds.

Working environment

Working temperature 0°C~40°C

Related humility ≤90% (+20±5°C)

atmospheric pressure70Kpa~106Kpa

Dimension

L*D*H(mm)485 mm *175 mm *85 mm      

Weight

5.5Kg

Packing.

520   *130 mm *200mm, 6.0kg

(YKDPZ-B) 18chs DC Distribution Cabinet system/ Intelligent PDU system/ Telecom Power Distributing Cabinet Intelligent PDU Visual-Aural Alarm

This DC power distribution system module can display the running status of all the channels. When there is failure or break, Red LED ON and buzzer sounds and giving the alarming signal to third party system for alarming

If you want to stop alarm, please press “SA” button. If there are others failure right now, there will be no alarm.

When there is failure again, RED LED still ON, and it will not OFF until the failure is eliminated and switch is turn on

(YKDPZ-B)18 channels Intelligent PDU /18chs dc Power Distribution Panel Installation and connection

4.1 install

   Easy and simple install. Standard 3.0U structure, can install in the standard 19 inch cabinet.

4.2 Connection

All the connection is on the rear panel.

Please connect with the anode, cathode and grounding as required. Please tighten the connection screw and nut. Connection must be steady and reliable to reduce the resistance.

4.3 Note.

Please don’t change or replace any wiring or air switch etc inside the dc power distribution system module. If you want to change or replay, please contact with manufactures.

Customer Satisfaction

Please don't hesitate to contact us if you have any questions or concerns before or after your purchase. We are committed to your 100% satisfaction.

Payment

T/T Payment in advance is the order value is less than 5000.00USD

Paypal. Western Union, credit card can be available

Shipping and handing

DHL, Fedex, TNT,UPS and EMS are available.

Notes

1. The buyer are responsible for any insurance you think necessary.

2. The processing time for a specific order varies with the product type and stock status. Mostly, processing time can be 3 to 15 working days.

3. All items must be returned in their original condition, in order to qualify for a refund or exchange of goods.

4.Items returned after 7 days of delivery are only eligible for repair.

5. The buyer is responsible for all shipping costs incurred.

Feedback

1. Since your feedback is very important to our business's development, we sincerely invite you to leave positive feedback for us if you are satisfied with our product

(YKDPZ-B) With high efficiency 18chs DC Distribution Cabinet system

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.