Welcome to ECVERY
NFC-2000Q Intelligent Power Distribution Monitor Terminal
NFC-2000Q Intelligent Power Distribution Monitor Terminal
Supplier Info
[China Supplier]
Contact Person : Ms. gao katherine
Tel : 0086-373-5010901
Fax : 0086-373-5010903
Product Detail
1)it is working by DL/T721-2000 distribution web auto systerm remote terminal 2)3-months data memery and harminic analysis

Products  Characteristic

1)more functions and high precision

Distribution intelligent monitoring terminal has strong data collect and disposal function and it can monitor dozens of (even hundreds )electric degree, at the same time ,it has 3-phase 4-wires voltage ,current harmonic real-time analysis of 3-19 times , electrical energy pulse output ,over electrical degree to alarm ,the most value record statistics, record 15minuts gap a kind of measuring quantity of electricity, data memory 3 months.

2)Communication grope web has strong function .

The communication function of distribution intelligent monitoring terminal is very strong .It has two ways light and electric separate RS-485/RS-232 gorge line one and RS-485 gorge line two .It support open way’s gorge communication pact and user can select different communication ways according to yourself need .The communication method can select UTP ,Coaxial Cable ,Data Radio and GPRS and it can compose high and economic electric monitor web with other monitor unit.

Display and operate easy

Distribution intelligent terminal monitor sampling 128*64 point LCD display and film button and maybe through button to select display measuring parameter or setting all of parameter. All of setting parameter  in the meter of not lose memory .If power cut ,the data will not lost ,otherwise user can use homologous system parameter setting to set software and through the communication to parameter setting.

4)Installation convenient and nimble

Distribution intelligent terminal monitor has two ways of installation of embedded chips and wall hanging chips , it can satisfy the request of different scene.

5)High safety

Distribution intelligent terminal monitor select a kind of anti-high jamming software /hardware step, it can safety and reliability to operate in strong magnetic field area and the reliability is so high.

Technology parameter:

Environment requirement :

High above sea level:≤2500m

Working temperature:-20°C~+60°C  Store temperature : -25°C~+70°C

Surrounding hasn’t  medium of corrosive gas, electric dust , inflammable and explosive. There are hasn’t knock cold and sleet corrode in installation place.

Working power : 220V±20% (A type)        85V~265V(B type )

Weight :1.5Kg

Measuring signal : split phase

Measuring method: AC sampling

Measuring voltage :59v~280v              Measuring current :0~5 A

Measuring power factory : lag0.200~ a head 0.200

Measuring harmonic :digital display

Measuring active power :0~999.9Kw(split phase)    

Measuring reactive power :0~999.9Kvar(split phase)

Measuring active electric degree :0~999999.99Kwh

Measuring reactive electric degree: 0~999999.99Kvarh

Input/output signal:

Reactive compensation output:12v  30mA/branch

The quantity of on/off output:12v   30mA/branch♣(need out delay)

The quantity of on/off input :main point output (needn’t out delay) ♣

Temperature quantity input:PT100

Alarm output :250v   5A DELAY MAIN POINT

Communication interface data:

RS-485

Communication interface 1: using in remote terminal data select

Method:RS-485/RS-232(to select use front panel bouncing pin)

Brand rate :1200,2400,4800,9600,38400

Data post:8 data post

Parity bit: can setting

Stop spot:1 stop spot

Communication interface 2: using on terminal and other intelligent equipment interface ♣

Method : RS-485

Brand rate:1200,2400,4800,9600,38400

Data post:8 data post

Parity bit: can setting

Stop spot:1 stop spot

Measuring accuracy:

Voltage : ±0.5%      Power : ±1.0%

Current  ±0.5%      Frequency: ±0.5%

Power factory: ±1.0%       Electric quantity: ±1.0%

Above data get for after 10min and within 1 year current .

Setting data:

Voltage upper limit: 240v~275v                    Step-length:5v      

Voltage lower limit: 175v~200v                    Step-length:5v

Goal power factory : 0.90~1.00                     Step-length:0.01

Current transformer ratio : 1~1200

Capacitor switching delay time :20mS~300S

Harmonic voltage setting data: 5%~50%             Step-length:0.5%

Tlock:0.5~1.2                                  Step-length:0.1

Zero sequence current :5%~50%                   Step-length:5%

Attention: “♣” is only Embedded structure product has the function .

NFC-2000Q Intelligent Power Distribution Monitor Terminal

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.