Smart Sanitary Rosemount Differential Pressure Transmitter/Sensor
Introduction
The MT3000s remote transmission differential pressure and pressure transmitter is a upgraded MT3000S transmitter equipped with remote transmission sealing device.
This transmitter can provides reliable measurement by avoiding medium tested contacting isolation diaphragm directly. It is applicable to situations listed below:
1. The medium tested has erosive effect to the transmitter interface and sensitive elements.
2. Need isolation between high temperature medium tested and the transmitter.
3. There are some suspended solids in medium or the transmitter interface and pressure chamber is blocked by high viscosity easily blocked substance.
4. Export easily solidified substance or crystallization in the medium with impulse the wire.
5. The renewal medium that needs washing and is hard to be mixed
6. Keep clear and avoid pollution
Function Parameters
1. Applicable Object: Liquid, gas, steam
2. Measuring range: 0~0.1KPa to 0~40MPa
3. Output Signal: 4~20mA DC
4. Power Source: 12~45V DC, 24V DC on average
5. Load Characteristic: Depend on power resource. The relation of RL and VS is: RL≤50 (VS-12)
6. Indicating Gauge: Multiple parameters and multiple ways LCD indicate header
7. EX-proof: a. Exd Type ExdllCT6 b. intrinsic safety Type ExidllCT4
8. Range and Zero Point: Outer continually adjustable
9. Positive And Negative Shift: When zero passes positive or negative shift, upper limit and lower limit of
measuring range cannot exceed 100% of upper limit. The maximum positive shift is 500% that of minimum
adjustment range; the maximum negative shift range is 600% that of minimum adjustment range.
10. Temp Range: Working temperature range of amplifier: -29~+93 °c (LT type: -25~+70°c)
11. Filling silicone oil measuring element: -40~+104°C
12. Filling High Temperature Oil to Flange Transmitter : +15~+315°C
13. Common Silicone Oil: -40~+149°C
14. Static Pressure: 4, 10, 25, 32MPa
15. Humidity: relative humidity 0~100%
16. Volume Absorb Quantity: <0.16cm3
17. Damping: Continually adjustable between0.2s and 1.67s when pouring oil.
Technical Parameters
1. Accuracy: ±0.1%, ±0.075%
2. Dead zone: No (≤0.1%)
3. Stability: Less than the absolute value of basic error of maximum range within 6 months.
4. Vibration Effect: With 200HZ vibration frequency and error that of ±0.05%/g upper limit of measuring
range in arbitrary axis
5. Power Source Effect: <0.005%/V output range
6. Load Effect: No load effect under stable power source
Product Details