Welcome to ECVERY
Thermocouple/1 wire temperature sensors
Thermocouple/1 wire temperature sensors
Supplier Info
[China Supplier]
Contact Person : Ms. Hu Jessie
Tel : 86-25-52366120
Fax : 86-25-52899138
Product Detail
Thermocouple/1 wire temperature sensors 1.All kinds of graduation 2. High stability and accracy

Thermocouple/1 wire temperature sensors

Normally, it isassembled with display instruments, recording instruments, computer, etc. It is direct used to measure site temperature of liquid, vapor, gas and solid surface with output 4-20mA.

Feature

Two-wire output 4-20mA, strong anti-jamming capability;

Save the costs of compensation wire and install temperature transmitter;

Safe, reliable, and long life;

Automatic compensation of cold junction temperature, non-linear correction circuit

Technical Parameters

Product performance standards

IEC584 IEC751 IEC1515 JB/T5518-91 JB/T7391-94

Temperature range and tolerance

1) thermal resistance

Model sub-degree temperature range, accuracy grade tolerances

SBWZ Pt100 -200 °C ~ +500 °C

           Class A

           Class B ± (0.15 +0.002 t)

± (0.30 +0.005 t)

        

SBWZ Cu50 Cu100 -50 °C ~ +100 °C --- ± (0.30 +0.006 t)

2) thermocouple

Model indexing Tolerance Level

Ⅰ Ⅱ

Tolerance value of the temperature range tolerance value of temperature range

SBWR K ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C

± 0.004t 375 °C ~ 1000 °C ± 0.0075t 333 °C ~ 1200 °C

SBWR N ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C

± 0.004t 375 °C ~ 1000 °C ± 0.0075t 333 °C ~ 1200 °C

SBWR E ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C

± 0.004t 375 °C ~ 1000 °C ± 0.004t 333 °C ~ 900 °C

SBWR J ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C

± 0.004t 375 °C ~ 1000 °C ± 0.004t 333 °C ~ 750 °C

SBWR T ± 0.5 °C -40 °C ~ +125 °C ± 1.5 °C -40 °C ~ +333 °C

± 0.004t 125 °C ~ 350 °C ± 0.0075t 333 °C ~ 350 °C

      

6, output Signal: 4-20 mA, load resistor 250, the transmission line resistance 100

7, Output Method: two-wire system

8, Accuracy:

Temperature Transmitter Accuracy class: 0.1 0.2 0.5

Display Accuracy class: 2.5 analog indication; figures show 0.5.

9, Power Supply: 24V.DC ± 10 %10, Protection: IP65

11, proof grade:

Flameproof: d Ⅱ BT4 d Ⅱ CT5 d Ⅱ CT6

Intrinsically Safe: ia Ⅱ CT6

12, the insulation resistance between the insulation resistance: meter output terminal and the shell should not be less than 50.

Thermocouple/1 wire temperature sensors