SP6 series steel mill pressure transducers are premium grade sensors.
Applied with no over travel stop technology, SP6 series has excellent over and burst pressure in application. Overload protection is an integral part in the SP61X transducers.Applications
Ø Steel and aluminum rolling mills
Ø Hydraulic/Pneumatic Control Systems
Ø Gas / Food production
Ø Military / commercial aircraft
Ø Farm machinery
General Specification at 25 degree C | ||||||||
Pressure Range | 0-5 Bar to 0-700 Bar | |||||||
Accuracy | 0.1% FS (0.15% Max) | |||||||
| - Combined Non-linearity, Hysteresis and Non-repeatability | |||||||
Sensor Element: | Foil strain gauge | |||||||
Material | ||||||||
| Diaphragm | 17-4 stainless steel | ||||||
| Housing | Stainless steel 304/316 | ||||||
Life | >108 Full Range Pressure | |||||||
Pressure limit | ||||||||
| SP61X | ≤4X Full Range or 800Bar, whichever is less | ||||||
| SP62X | ≤2X Full Range or 800Bar, whichever is less | ||||||
Burst Pressure | ||||||||
| SP61X | ≤20X Full Range or 1500Bar, whichever is less | ||||||
| SP62X | ≤5X Full Range or 1500Bar, whichever is less | ||||||
Long Term Drift | <0.1% SPAN | |||||||
Weight | <180g | |||||||
Pressure Reference | Seal Gauge (SG) | |||||||
Vent Gauge (VG) | ||||||||
Absolute (A) | ||||||||
Environmental Performance | ||||||||
Humidity | ||||||||
| Cable outlet | IP67 | ||||||
| Connector outlet | IP65 | ||||||
Temp. | ||||||||
| Operational | -50 to 120 degree C | ||||||
| Compensated | -20...+80 degree C | ||||||
Shock | 1000g,5msec | |||||||
Vibration | MIL STD810C, Method 514-2 Curve L | |||||||
Electrical: | ||||||||
Thermal Shift | ±0.015%SPAN/ (-2080) | |||||||
Frequency Response | 900Hz | |||||||
Insulation | Min 500MΩ @ 50VDC & 25 | |||||||
Noise | < 2m VRMS | |||||||
Output | SP6X1 (4-20mA) | SP6X2 (0-5V) | SP6X3 (0-10V) | |||||
Input Voltage | 10V-36V | 18-32V | 18-32V | |||||
Zero Output | 4mA± 0.5%SPAN | 0V± 1%SPAN | 0V± 1%SPAN | |||||
Full Range Output (SPAN) | 16mA± 0.5%SPAN | 5V± 1%SPAN | 10V± 1%SPAN | |||||
Load resist. | 01200Ω | - | - | |||||
Impedance | - | < 15Ω | <15Ω | |||||
Output Current | - | < 6 mA | < 6 mA |