Welcome to ECVERY
G3NA-290B-UTU DC5-24 solid state relay
G3NA-290B-UTU DC5-24 solid state relay
Supplier Info
[China Supplier]
Contact Person : Ms. Du Miranda
Tel : 0086-022-27373707
Fax : 0086-022-27373701
Product Detail
solid state relay AC Output Relays with 75-A and 90-A output currents Operation indicator enables monitoring operation

G3NA-290B-UTU DC5-24 solid state relay

specification 

Ratings

Product classification

Solid State Relay for heater control

Operating Rated Voltage

5 to 24 VDC

Operating Voltage Range

4 to 32 VDC

Input Impedance

15 mA Max.(at 25 CEL)

Must Operate Voltage

4 VDC Max.

Must Release Voltage

1 VDC Min.

Isolation

Phototriac

Output Form

SPST-NO

Rated load voltage

24 to 240 VAC (50/60Hz)

Load Voltage Range

19 to 264 VAC (50/60Hz)

Load Current

AC: 1 A to 90 A (With heat sink (at 40 CEL))AC: 1 A to 7 A (Without a heat sink (at 40 CEL))

Inrush Current Resistivity

AC: 1000 A (60Hz 1 cycle)

Output ON voltage drop

1.6V(RMS) Max.

Leakage current

5mA Max. (at 100VAC)10mA Max. (at 200VAC)

Ambient temperature

Operating: -30 CEL to 80 CELStorage: -30 CEL to 100 CEL(with no icing or condensation)

Ambient humidity

Operating: 45% RH to 85% RH(with no icing or condensation)

Characteristics

Operate time

1/2 cycle of load power source + 1ms Max.

Release time

1/2 cycle of load power source + 1ms Max.

Protection for output

Varisitor and Snubber

Zero cross function

Provided

Indicator

Equipped

Insulation resistance

Between INPUT to LOAD: 100 M Ohm Min. (at 500 VDC)Between Heat Sink to INPUT/OUTPUT Terminals: 100 M Ohm Min. (at 500 VDC)

Dielectric strength

Between INPUT to LOAD: 4000 VAC 50/60 Hz for 1 minBetween Heat Sink to INPUT/OUTPUT Terminals: 4000 VAC 50/60 Hz for 1 min

Vibration resistance

10 to 55 to 10Hz 0.75mm single amplitude(1.5mm double amplitude)XYZ directions for 2hrs each

Shock resistance

1000m/s2 each XYZX'Y'Z' directions for 3 times

Applicable standard (UL)

Standard No.: UL508 , UL1950File number: NO.E64562 , NO.E64562

Applicable standard (CSA)

Standard No.: C22.2 NO.14 , C22.2 NO.950File number: No.LR35535 , No.LR35535

Applicable standard (TUV)

Standard No.: EN60947-4-3File number: NO.R 50042088

Terminal structure

screw

Terminal strength (Clamp torque)

Input terminal: Recomendable fasten torque M4: 0.98 to 1.47N.mOutput terminal: Recomendable fasten torque M5: 1.57 to 2.45N.m

Mounting

screw , panel , panel(DIN track)

Weight

Approx. 120 g

G3NA-290B-UTU DC5-24 solid state relay

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.