Welcome to ECVERY
Wide Range 1500 Resistance FLUKE 1630 Earth Resistance Tester for Ground loop Resistance Measuremetn
Wide Range 1500 Resistance FLUKE 1630 Earth Resistance Tester for Ground loop Resistance Measuremetn
Supplier Info
[China Supplier]
Contact Person : Ms. Chow Tracy
Tel : 86-755-26509606-8803
Fax : 86-755-26502620
Product Detail
FLUKE 1630 earth resistance tester Ground earth tester clamp earth tester F-1630 clamp resistance tester

The Fluke 1630 Earth Ground Clamp Meter is able to measure ground loop resistances - using the Stakeless testing method.  This test technique eliminates the dangerous, and time consuming activity of disconnecting parellel grounds, as well as the process of finding suitable locations for auxiliary ground stakes.  You can also perform earth ground tests in places you have not considered before:  inside buildings, on power pylons or anywhere you don't have access to soil.With the Stakeless testing method, the Fluke 1630 Earth Ground Clamp Meter is placed around the earth ground rod or the connecting cable.  No earth ground stakes are used at all.  A known voltage is induced by one half of the clamp and the current is measured by the other half.  The tester automatically determines the ground loop resistance at this grounding connection.  Gone are the days of spending time placing and connecting stakes for each ground rod on your system - a major time saver.What's Included:

Rugged carrying case with shoulder strapResistance test loop9 V batteryUser's manual in English, French, Spanish, German, Italian, Portuguese, and Simplified Chinese

Features:

A wide ground loop resistance range, from 0.025 Ω to1500 Ω, to satisfy all requirementsLarge jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus barsMeasurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshootingWide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applicationsUser-defined HI / LO Alarm limits, for rapid measurement evaluationHandy ‘display hold’ button for capturing readings in hard-to-reach placesTime saving memory function automatically records and stores measured valuesAutomatic self calibration ensures correct measurement every timeOverload protection: 200 ACarrying case and resistance test loop included≥ 8 hours battery life (continuous operation)
General Specifications
Operating error
 Refers to the operating temperature range and is guaranteed for 2 years
Storage temp. range
 -20 °C to 60 °C (-4°F to 140 °F)
Reference temp. range
 23 °C ± 5 °C (73 °F ± 9 °F)
Storage humidity
 <75 % Rh
Operating humidity
 <85% Rh
Display
 999 digital LC display with special symbols
Protection
 IP30 according to IEC 529/EN 60529
Safety
 300 V, CAT III pollution degree 2 IEC 61010-1 and IEC 61010-2-032
Weight
 750 g (1.165 lbs)
Conductor size
 35 mm (1.38 in) approximately
Dimension (length x width x depth)
 276 mm x 100 mm x 47 mm (10.8 in x 3.9 in x 1.9 in)
Emission
 IEC 1000 4-2, IEC 61326-I class B
Immunity
 IEC 61000-4-2, 8 kV (air) criteria A
 IEC 61000-4-3, 3 V/m performance criteria A
Range selection
 Auto
Overload indicator
 "OL" on display
Measuring time
 0.5 sec
Measuring frequency
 3.333 kHz
Battery type
 9 V alkaline (type IEC 6 LR 61)
Battery life
 ≥ 8 hours (continuous operation)
Power consumption
 40 mA
Low battery indication
 Display symbol
Ground Loop Resistance (Autorange)
Range
 Accuracy(± % of reading Ω)
0.025 - 0.250 Ω
 ± 1.5 % rdg ± 0.02 Ω
0.250 - 9.999 Ω
 ± 1.5 % rdg ± 0.05 Ω
10.00 - 99.99 Ω
 ± 2.0 % rdg ± 0.3 Ω
100.0 - 199.9 Ω
 ± 3.0 % rdg ± 1.0 Ω
200.0 - 400.0 Ω
 ± 5.0 % rdg ± 5 Ω
400.0 - 600.0 Ω
 ± 10 % rdg ± 10 Ω
600.0 - 1500 Ω
 ± 20 %
Note:
 Loop resistance with no inductance, external magnetic field < 50A/m, external electrical field < 1 V/m, conductor centered.

Wide Range 1500 Resistance FLUKE 1630 Earth Resistance Tester for Ground loop Resistance Measuremetn

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.