Welcome to ECVERY
Hirschmann pressure transmitter
Hirschmann pressure transmitter
Supplier Info
[China Supplier]
Contact Person : Ms. Wang Evelyn
Tel : 86-29-81879753,18691638115
Fax : 86-29-88888109
Product Detail
1. Accuracy:0.25%F.S 2. Various of pressure range 3. Thread mounted 4. CAN bus-out 5. Gas and liquid pressure detection

1. Parameter

Spec.

Value

Pressure range

0~2Mpa….60Mpa

Overload pressure

1.5 times nominal pressure

Secondary Containment

3 times nominal pressure

Accuracy

±0.25%F.S

Working current

<70mA

Operating temperature

-40°C~85°C

Compensated Temperature Range

-20°C~85°C

Protection grade

IP65

Communication distance

Max. 10km

Power supplier

10~30Vdc

Communication speed

1Mbps

Electric connection

Hirschmann

Pressure port

M20×1.5, G1/4, G1/2, R1/2, NPT1/2

Pressure type

G, S G

Specification support

Support CAN2.0A and CAN2.0B

Protocol support

Support CAN open protocol

2. Electronic interface and signals definition

Hirschmann joint:

1——VIN+

2——VIN-

3——CANH

——CANL

3. Feature

Accuracy : 0.25% F.S

Various pressure range

Thread mounted

CAN bus out

4. Application

Hydrologic monitoring

Constant voltage water supply  

Frequency conversion water supply

Tail dam water level

Sewage treatment

( function(){ var aBigImageSrc = [ 'http://i01.i.aliimg.com/photo/v1/686908275_1/Hirschmann_pressure_transmitter.jpg' , 'http://i01.i.aliimg.com/photo/v1/686908275_2/Hirschmann_pressure_transmitter.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); Hirschmann pressure transmitter