double ended shear beam load cell
Dimensions(mm)
Specifications
Emax(Max. capacity) | klb | 25~125 | |
Sensitivity | mV/V | 3.0±0.003 | |
Accuracy class | C2 | C3 | |
Maximum number of verification intervals | nmax | 2000 | 3000 |
Minimum load cell verification interval | Vmin | Emax/5000 | Emax/10000 |
Combined error | %F.S | ≤±0.030 | ≤±0.020 |
Creep | %F.S/30min | ≤±0.024 | ≤±0.016 |
Temperature effect on sensitivity | %F.S/10°C | ≤±0.017 | ≤±0.011 |
Temperature effect on zero | %F.S/10°C | ≤±0.023 | ≤±0.015 |
Zero balance | %F.S | ±1.0 | |
Input resistance | Ω | 750±10Ω | |
Output resistance | Ω | 702±3Ω | |
Service temperature range | °C | -30...+70 | |
Safe overload | %F.S | 150 | |
Ultimate overload | %F.S | 250 | |
Recommended excitation voltage | V | 5…15 | |
Insulation resistance | MΩ/50V | ≥ 5000 | |
Protection class | IP67/IP68 | ||
Load cell material | Alloy steel / Stainless steel | ||
Cable Size | 12m | ||
Cable color code: Exc+[Red] ; Exc-[Black] ; Sig+[Green] ; Sig-[White] ; Shield[yellow] |
Features
lBridge type double shear beam, unique floating bearing structure
lSelf-resetting , good side force resistance and shock resistance
lMoisture-proof sealed , ideal for hostile environment
lSimple to install , easy to use , good interchangeability
Application
truck scales,rail scales,bin and hopper scales,etc.
weighing bridge Double Ended Shear Beam Load Cell (QSC)