Product Detail
Model HC02 High quality and precision Excellent linearity and low power consumption Wide measurement range Anti-pollution

High quality and precision!

Produced using unique semiconductor technology, so the HC02 can be utilized in most occasions.

Features:

Excellent linearity

Low power consumption

Wide measurement range

Quick response

Anti-pollution

High stability

Dehumidifying quickly after long-term saturation

High performance-price ratio

Technical Specification:

Operating range:                    0-100%RH     -40~130Celsius

Power supply:                      10V AC (Max)

Nominal capacitance:                200+-10pF(25Celsius, 60%RH)

Sensitivity average:                  0.5pF/%RH

Humidity effects:                    +1Celsius, +0.025pF

Power consumption factor:             <0.01

Return difference of humidity hysteresis:  <1%RH

Linear error:                         <+-2%RH

Response time:                       <5s

Operating frequency:                  5k--100kHz

Recovering time after 150 hours dew condensation:  <10s

Stability:                            <1%RH/Year

Dimensions:                        with case 6.5*10*3mm, without case 5*7*0.6mm