Wanji designs and manufactures EI Lamination Power Transformer to meet the demands of different power, insulation and mounting under using various international standards of bobbins. This series of transformers are relatively economic and easy mounting with wide application.
Specification:
Power Range: 3VA -2000VA
Input/Output: Customized
Insulation Class: UL class B, F, H, N. (Optional)
Isolation: 3.75KV(Hi-pot )
Model | Spec. | Power(VA) | Dimension(mm) | Installation Size(mm) | HoleDia.(mm) | Weight(Kg) | Approval | ||
A | B | C | D | E |
| ||||
EI35 | 35*15 | 3 | 61 | 35 | 32 | 48 | 3.9*7 | 0.14 | UL/CE/RoHs/CQC |
EI41 | 41*16 | 5 | 67 | 34 | 37 | 54 | 3.9*7 | 0.19 | UL/CE/RoHs/CQC |
41*26 | 8 | 70 | 45 | 37 | 55 | 3.8*7 | 0.29 | UL/CE/RoHs/CQC | |
EI48 | 48*20 | 10 | 77 | 39 | 43 | 60 | 3.9*7 | 0.32 | UL/CE/RoHs/CQC |
48*24 | 12 | 74 | 45 | 43 | 60 | 3.9*7 | 0.36 | UL/CE/RoHs/CQC | |
EI57 | 57*25 | 18 | 88 | 48 | 50 | 73 | 3.9*7 | 0.55 | UL/CE/RoHs/CQC |
57*30 | 25 | 90 | 53 | 50 | 74 | 3.9*7 | 0.66 | UL/CE/RoHs/CQC | |
EI66 | 66*28 | 30 | 93 | 56 | 58 | 79 | 4.8*7 | 0.81 | UL/CE/RoHs/CQC |
66*40 | 55 | 96 | 68 | 59 | 82 | 4.8*7 | 1.2 | UL/CE/RoHs/CQC | |
EI76 | 76*32 | 65 | 110 | 64 | 67 | 96 | 4.8*7 | 1.35 | UL/CE/RoHs/CQC |
76*45 | 100 | 106 | 75 | 67 | 90 | 4.8*8 | 1.8 | UL/CE/RoHs/CQC | |
EI86 | 86*40 | 130 | 117 | 75 | 75 | 101 | 4.8*8 | 2.1 | UL/CE/RoHs/CQC |
86*45 | 150 | 117 | 80 | 75 | 101 | 4.8*8 | 2.4 | CE \UL\RoHS |
Remark: All data are subjected to modification without prior notice.
EI Power Transformer