Welcome to ECVERY
high efficiency solar power system off-grid
high efficiency solar power system off-grid
Supplier Info
[China Supplier]
Contact Person : Mr. Yee Alex
Tel : 86-538-2820288,2833566
Fax : 86-538-2833599
Product Detail
It's compactness and portability with high power generation efficiency, AC & DC output.

The shell of this series of products with nano-plastic-sprayed crafts has strong adhesion that suitable to tropic areas. This product is portable, fully functional, super stability and high life.

This series of products are necessary for household use, mobile office, field operations, blackout emergency, they apply to electricity voltage AC220V, 50Hz, DC12V, and the power in the range of rated power, for example: mobile phone charging, flashlight charging, lantern charging, radios, notebook computers, digital cameras, video camera, televisions, computers, small power electric tools, music CD, DVD, fans, DC/AC lights, etc.

Illustration directions:

 

1. Controller

2. AC switch

3. USB output

4. Control box

5. External battery connection

6. AC output

7. DC input

8. DC output

9. Handle

10. Inverter (500W Interior)

WDF-214 is necessary for household use, field operations, mobile office, blackout emergency, it applies to electricity voltage AC220V, 50Hz, DC12V, and the power in the range of rated power, for example: mobile phone charging, flashlight charging, lantern charging, radios, notebook computers, televisions, computer, small printer, fax machine, digital cameras, music CD, DVD, fans, DC/AC lights, etc.

Note: Please use products within rated power range(400W), do not overload.

.

1. Please install solar panels outdoor under the Sun, the surface of solar panels are positioned vertically with the sunlight as far as possible.

2. Installation and connection according to the positive pole and negative pole on the back of the solar panels.

I Use environment

Based on the consideration of safety and performance, this series of products’ installation environment should meet the following conditions:

1. Dry: Not flooding or rain.

2. Shade: Temperature should between 0 °C -50 °C.

3. Ventilation: Keep the product installation location is a well-ventilated.

4. This series of products should be installed with the battery in the same place; the connection between products to the battery is no more than 1 meter, so we can detect battery voltage and ambient temperature conveniently and accurately to adjust the charging status and reducing losses.

5. Solar panels are used outdoors; do not afraid the wind and rain, installation angle should be vertically with the sun as far as possible.

II Installation steps

This series of products mainly divided into 4 parts: solar panels, battery, control box, other accessories.

Step 1: Check all parts for damage.

Step 2: Connect the battery according to the positive and negative pole of the control box outer wires, and then check the connection is intact.

Step 3: Connect panels, pay attention to the panels’ positive and negative pole, and then insert the plug into DC input and check charging.

Step 4: Select the appropriate USB output according to the need: AC output/DC output, and then connect load.

III Part description

1. Controller

This series of products adopt the new generation of intelligent solar charge controller with a super stability and high life.

LED lights indicator Function:

Green light (L1) is Charge indicator; red light (L5) is load indicator; yellow lights (L2, L3, L4) is battery capacity indicator. System will self-test after connect the battery; green light, red light and yellow lights flare, and then the red light extinguisher, the yellow lights are normal and display the battery power, which means the system is normal. Green light (L1) bright means solar panels are supplying power, if not, no power supply. Red light (L5) bright normally means system is in discharge protection, red light (L5) flare means overload or short circuit, red light (L5) extinguish means load normal. Yellow lights (L2, L3, L4), from left to right respectively the battery capacity: > 75%, 25 to 75%, <25%. Yellow light (L4) bright means the battery voltage is low, yellow light (L4) flare means voltage is very low and the controller is about to cut off the load output.

2. AC switch

When the switch I is pressed, the AC output can be used; the AC output is stopped when the switch O is pressed.

3. USB output

USB output can charge the phone with a USB data cable directly. This series of products is also supporting multi-function phone charging cable which simultaneously to different mobile phone charging.

4. Control box

The control boxes of this series of products using nano-plastic-sprayed process. Novel designed, beautiful appearance and durable.

5. External battery connection

Connect the batteries through an external line and pay attention to the positive and negative polarity (red wire to battery positive).

6. AC output

Output voltage: AC 220V±5%,50HZ, can be used to computer, television, fan, AC lighting, stereo, need charging appliance ( small power AC appliance, such as: mobile phone, flashlight, lantern, etc).

7. DC input

This socket is used for the solar panel cable input (Note: connect the battery firstly, and then insert the solar panel cable).

8. DC output

DC output voltage is 12V which can be used for DC lights, etc.

9. Handle

The handle is made of 304-type stainless steel. Bright surface, feels comfortable and convenient to carry.

10. Inverter (Interior)

Inverters of this series of products have different specifications that can provide safety and reliably AC power. If the inverter is used continuously, the inverter surface temperature will rise to 60 °C, so please keep the air circulation, in order to avoid the inverter is damaged.

IV Common faults and exclusion method

Fault appearance

Controller LED lights display

Cause of the fault

Elimination method

No output of the panels, the battery can not change

(L1 )The charge indicator light does not shine

Panels connecting line fault, positive and negative reversed

Check the panels and connecting line, eliminate the fault

Battery short time with no power

(L5) Red light bright

Battery bad or damaged

Change the battery

Battery charge is not enough

Cut off the load until the battery is fully charged before use

Attenuation of current through the wire

Shorten the wire, use overstriking wire

System no DC output

(L5) Red light bright

The battery has no power

Check the battery is in good condition, fully charged and the battery connection cable

(L5) Red light flare

Load over current or short-circuited protection

Cut off all the loads, eliminate the fault, and the system will automatically resume after one minute

System no AC output

AC switch is not open

Check the AC switch and open it

Battery power is done (inverter alarm)

Charging or replace the battery

The appliance rated power is more than inverter nominal power, causing the overload shutdown

Use appliance rated power less than inverter nominal power

The appliance power less than inverter nominal power, but high peak power, causing the overload shutdown

Use appliance peak power in accordance with the inverter

Poor ventilation, causing over-temperature shutdown

Turn off the inverter and cool for 15minites.Remove the goods around the fan and inverter, reduce the load by requirement, and then restart it.

Inverter input voltage is too high

Check the charging system and the output voltage of battery

The inverter warning

Under-voltage or over-temperature protection

Shorten the wire or use overstriking wire; charge the battery; improve the ventilation around the inverter and coo it; reduce the load by requirement

Inverter can only be driven by low-power load

The voltage attenuation when current through the wire

Shorten the wire or use overstriking wire

V Matters needing attention

1. This series of products are not suitable for children operating by themselves.

2. This series of products strictly forbid overload, load power shall not exceed the rated power.

3. Try to avoid the too cold, heat, dust, damp environment using.

4. This series of products factory settings for the maintenance-free lead-acid batteries (liquid cell). If do not use for a long time, should keep the battery full charge timely (once a month at lease), otherwise battery will be permanently damaged.

high efficiency solar power system off-grid