Product Detail
total module surface up to c. 221 ft 2; 20.5m2 no unnecessary tracking movements low power consumption 1 kw DC linear drive

Nakin Solar Tracking system Single-Axis Tracking System

Model: DT2000

Module surface of 221 ft², max power installed: c. 3.6 kWp, second axis: manually adjustable stepwise 0 – 45°

Characteristicstotal module surface up to c. 221 ft²no failure-prone light sensorno unnecessary tracking movementslow power consumption(c. 1.5 kWh/year)statics according to German and European standardshigh reliability and life-expectancymaintenance-freecost-efficient tracking systemApplicationsingle-axis tracking system for PV modules*additional energy yield of up to 40 % compared to fixed installationsDesign

Tracking Unit

single-axis tracking systemangle of second axis adjustable 0 – 45° in steps of 5°elevation East-West: 90°module surface up to c. 67.25 ft² max.dimensions of mounted frames (supportive area, installation area PV modules): width: 11.48 ft, height: 19.35 ft, up to four rows of PV modules in upright positionframe and pole: steel, hot-dip Zn-coatedscrew set: steel, Zn-coatedmodule clamps made of stainless steel for mounting the PV modules using the holes in the module frame, incl. M6 stainless steel screw kitssuitable for high wind speeds: statics according to German and European standardslow energy consumption c. 1.5 kWh/yearmaintenance-free

Control

electronics incl. battery in plastic housingsupply voltage: 12 V DC (nominal voltage) up to 50 Voc (open-circuit voltage), by one of the tracked modules**stepwise tracking, depending on the daily sunshine duration (length of day)South position in darknesssynchronisation of multiple units possiblestandby mode in periods of low irradiation***

Drive

DC linear drivemaintenance-free

Foundation

concrete foundation with steel reinforcement (min. 13.12 ft³)

Storage & Operating Conditions

ambient temperature range: –13 °F to +122 °Fdaily average ambient humidity: max. 80 %air salinity: max. 2 µg/m3, or distance from coast: min. 1 kmaltitude: –1,312 ft to +9,842 ft MSLfor detailed description of ambient conditions for safe operation, cf. installation manualdesigns for other conditions on request

* for framed PV modules according to IEC 61215, UL 1703** for safe operation in specific system designs, an additional small module might be necessary, cf. installation manual*** for safe operation, cf. installation manual

Characteristicstotal module surface up to c. 65 ft²