WFX-210 Atomic Absorption Spectrophotometer, Fully automatic flame and furnace type,6-lamp turret,D2&S-H background correction Atomic Absorption SpectrophotometerModel: WFX-210 FETURES:1 Integrated flame/graphite furnace atomization system, changeable with flame emission burner

1.1 Automatically controlled changeover of the integrated flame and graphite furnace atomizer featuring easy operation and time saving eliminates human labor

1.2 A flame emission burner head can be installed to perform flame emission analysis to akali metais as K, Na etc.

2 Accurate fully automated control system

2.1 Automatic 6-lamp turret, automatic adjustment of lamp current and optimization of light beam position

2.2 Automatic wavelength scanning and peak picking

2.3 Automatic spectral bandwidth changing

2.4 Automatic changeover between flame and graphite furnace operation, automatic optimization of position parameters, automatic ignition and automatic gas flow setting

3 Reliable fully automatic graphite furnace analysis

3.1 Adopting FUZZY-PID and dual curve mode light-controlled temperature control technique, temperature auto-correction technique, ensures fast heating, good temperature reproducibility and high analytical sensitivity. The temperature control accuracy is less than 1%

3.2 Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact

3.3 Multi-function autosampler features automatic standard sample preparation, automatic correction of sampling probe depth, automatic tracing and correction of liquid surface height in the sample vessel, with the sampling accuracy of 1% and reproducibility of 0.3%, realizing fully automation of graphite furnace analysis 5 Perfect safety protection measures

4.1 Alarm and automatic protection to fuel gas leakage, abnormal flow, insufficient air pressure and abnormal flame extinction in flame system

4.2 Alarm and protection function to insufficient carrier gas and protective gas pressure, insufficient cooling wate supply and over-heating in graphite furnace system

5 Advance and reliable electronic design

5.1 Adopting large-scale programmable logic array and Inter I2C bus technology

5.2 European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system

6 Easy and practical analysis software

6.1 Easy-to-use AAS analysis software is made under Windows operating system, realizing fast parameter setting and

optimization

6.2 Automatic sample dilution, automatic curve fitting, automatic sensitivity correction

6.3 Auotmatic calculation of sample concentration (content), mean value, standard deviation and relative standard deviation calculation

6.4 Mutil-elements determination in sequence to the same sample

6.5 Measured data and final results can be printed out and edited in Excel format

SPECIFICATIONS:

Main Specification

Wavelength range

190-900nm
Wavelength accuracyBetter than ±0.25nm
ResolutionTwo spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability0.004A/30min
Background correction
The D2 lamp background correction capability at 1A is better than 30 times
The S-H background correction capability at 1.8A is better than 30 times.
Light Source SystemLamp turretMotorized 6-lamp turret ( Two high performance HCLs can be mounted on the turret to increase the sensitivity in flame analysis.);
Lamp current adjustmentWide pulse current: 0~25mA,Narrow pulse current: 0~10mA
Lamp power supply mode

400Hz square wave pulse;

100Hz narrow square wave pulse+400Hz wide square wave pulse

Optical SystemMonochomatorSingle beam, Czerny-Turner design grating monochromator
Grating1800 l/mm
Focal length277mm
Blazed Wavelength250nm
Spectral Bandwidth0.1nm, 0.2nm, 0.4nm, 1.2nm, auto-switch over
Flame AtomizerBurner10cm single slot all-titanium burner
Spray chamberCorrosion resistant all-plastic spray chamber
NebulizerHigh efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min
Emission burner provided
Graphite FurnaceTemperature rangeRoom temperature~3000ºC
Heating rate2000°C/s
Graphite tube dimensions28mm(L)×8mm(OD)
Characteristic massCd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
PrecisionCd≤3%, Cu≤3%, Mo≤4%
Detection and Data Processing SystemDetectorR928 Photomultiplier with high sensitivity and wide spectral range.
SoftwareUnder Windows operating system
Analytical methodWorking curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.
Repeat times1-99 times, automatic calculation of mean value, standard deviation and relative standard deviation.
Multi-task FunctionsSequential measurement for multi-element determination to the same sample
Condition readingWith model function
Result printingMeasurement data and final analytical report printout, editing with Excel
Standard RS-232 serial port communication
Graphite Furnace AutosampleSample tray capacity55 sample vessels and 5 reagent vessels
Vessel materiaPolypropylene
Vessel volume3ml for sample vessel, 20ml for reagent vessel
Minimum sampling volume1μl
Repeatable sampling times1 -99 times
Sampling systemAccurate dual pump system, with 100μl and 1ml injiectors
Characteristic Concentration and Detection Limit

Air-C2H2 flame

Oxygen-rich Air-C2H2 flame

Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Ba: Characteristic concentration ≤ 0.22mg/L
Al: Characteristic concentration ≤ 0.4mg/L
Function ExpansionHydride vapor generator can be connected for hydride analysis

 