Welcome to ECVERY
LR1106 12V 250W DC BOARD
LR1106 12V 250W DC BOARD
Supplier Info
[China Supplier]
Contact Person : Mr. Wu Simon
Tel : 86-755-26996161-826
Fax : 86-755-26996644-860
Product Detail
DC-DC power supply boardsupply 1 overcurrent protection ,overvolatege protection 2thermal protection 3short-circuit protec

    

INPUT REQUIRED: 

INPUT VOLTAGE RANGE:11.2VDC—14.8VDC

INCOMING CURRENT RANGE:12.0A Max @11.2VDC

INPUT SURGING CURRENT:12.0Vmax@12VDC

WORK EFFICIENCY≥85%

         OUTPUTREQUIRE:FIVE GROUPS OF POWER OUTPUT                                       TESTING EMPHASIS

Item

Output voltage

Output current(A)

min(V)

avg(V)

max(V)

ripplewave(mV)

Sb current

avg

peak

+3.30V

+3.14

+3.30

+3.47

50

0

8.0

10.0

+5.00VSB

+4.75

+5.00

+5.25

50

1.0

1.6

2.0

+5.00V

+4.75

+5.00

+5.25

50

0

8.0

10.0

+12.00V

+11.20

12.00

+12.8

120

0

10.0

13.0

-12.00V

+10.80

-12.00

-13.20

120

0

0.1

0.15

      Input/output interface

 

 

INPUT                                                                                  OUTPUT

 

 

         Defencive fuction  (for+3.3V,+12V,+5.00V&+5.00VSB power output)

OCP: output shut down when output current reaches the peak point.

Short-circuit protection:output shut down when short-circuit.   

                    

      PSU timing sequence; 

 

 

 

 

 

     Environment description: 

Working temperature/humidity       15°C to 35°C / 45%-75%

Reposition temperature//humidity   -40°C to +70°C/ 10%-90%

Atmospheric pressure            86Kpa—106Kp

     

LR1106 12V 250W DC BOARD