Features:
1. Universal AC input/ full range
2. Protections: short circuit / over load/ over voltage
3. Cooling by free air convection
4. 100% full load burn-in test
5. 2 years warranty
Mode Specification | T-30A | T-30B | ||||
CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC output voltage | 5V | 12V | -5V | 5V | 12V | -12V |
Output voltage error (Note2) | ±2% | +2,-6% | +2,10% | ±2% | +2,-6% | ±6% |
Rated output current | 3A | 1A | 0.5A | 3A | 1A | 0.5A |
Output current rage | 0.5-3A | 0.1-1A | 0.1-0.5A | 0.5-3A | 0.1-1A | 0.1-0.5A |
Wave and noise(Note3) | 50mVp-p | 100mVp-p | 50mVp-p | 50mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note4) | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% |
Load stability(Note5) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 30W | 33W | ||||
Efficiency | 70% | 72% | ||||
Adjustable range for DC voltage | CH1+10,-5% | CH1+10,-5% | ||||
AC input voltage range | 85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC | |||||
Input current | 0.8A/115V 0.45A/230V | |||||
AC impulse current | Cold-start current 18A/115V 36A/230V | |||||
Leakage current | <0.5A/240VAC | |||||
Overload protection | 105%~150% Type:FOLDBACK Pulsing hiccup shutdown Reset. auto recovery | |||||
Over-voltage protection | …… | |||||
High-temperature protection | …… | |||||
Temperature coefficient | ±0.03%°C(0~50°C) ON+5V OUTPUT | |||||
Setup rise hold up time | 200ms,100ms,30ms | |||||
Vibration | 10~500Hz,2G 10min./1cycle,Period for 60min,Each axes | |||||
Withstand voltage | Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | |||||
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms | |||||
Working temperature and humidity | -10°C~+60°C,20%~90%RH | |||||
Store temperature and humidity | -20°C~+85°C,10%~95%RH | |||||
Overall dimension | 129*98*38mm | |||||
Weight | 0.4Kgs | |||||
Safety standards | Meet UL1012 requirement(not apply for the mark) | |||||
EMC standards | Meet FCC Part 15J Conduction class A | |||||
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2,3,11must be knocked down. |
T-30 triple output switching power supply for good quality