SPECIFICATIONS | |
| |
INPUT | |
Voltage Range | 85132 VAC/170264VAC4763 Hzselected by switch240370VDC |
AC Current | 1.3A/115 V 0.65A/ 230 V |
Efficiency | 71%(SKS-50-5); 78%(SKS-50-12); 78%(SKS-50-15); 82%(SKS-50-24); 84%(SKS-50-48); |
Inrush Current | Cold start18A/115V 36A/230V |
Leakage Current | 1 mA/240VAC |
| |
OUTPUT | |
| |
PROTECTION | |
Over Load | 110%160% |
| Protection type: Fold back current limiting, recovers automatically after faultlt condition is removed |
| |
ENVIRONMENT | |
Working Temp., Humidity | -10+6020%90 %RH |
Storage Temp., Humidity | -20+8510%95 %RH |
Vibration | 10500Hz,2G 10min./1cycle,period for 60min, each along X, Y, Z axes |
| |
SAFETY | |
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
| |
STANDARD | |
Safety Standard | Design refer to UL1012 |
EMC Standard | Design refer to FCC Part15 J Conduction Class B |
| |
OTHERS | |
Weight | 0.51Kg |
Packing | 24pcs/13.1Kg/0.7CUFT |
| |
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. |
| 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12twisted pair-wire terminated with a 0.1μ &47μ parallel capacitor. |
| 3.Tolerance: includes set up tolerance, line regulation and load regulation |
| |
OUTPUT | |