small size,high reliability,universal AC input/full range, complete protection function,high efficiency

Feature

·Universal AC input/full range·Protections:Short circuit/Over load/Over voltage·Cooling By free air convection·LED indicator for power on·100% full load burn-in test·All using 105°C long life electrolytic capacitors·Withstand 300VAC surge input for 5 second·High operating temperature up to 70°C ·Withstand 5G ·vibration test ·High efficiency,long life and high reliability·1 year warranty ·Dimension: 159*97*38mm (L*W*H) 

SPECIFICATIONS

INPUT

Voltage Range:AC 88~264VAC    DC 125~373VDC(Withstand 300VAC surge for 5sec,Without damage)

Frenquency:47-63Hz

AC Current:2.5A/ 115AC   1.5A/230VAC

Efficiency:74%(HSC-100-3.3) ;77%(HSC-100-5);81%(HSC-100-12);82%(HSC-100-15);84%(HSC-100-24);84%(HS-100-48)

Inrush Current:Cold start 40A/230VAC

Leakage Current:< 2 mA/240VAC

OUTPUT

PROTECTION

Over Load:110%-150%

Protection Hiccup mode,recovers automatically after fault condition is removed

Over voltage:3.8-4.45V (HSC-100-3.3) ; 5.75-6.75V (HSC-100-5); 13.8-16.2V (HSC-100-12); 17.25-20.25V (HSC-100-15); 27.6-32.4V (HSC-100-24); 55.2-64.8V (HSC-100-48);

ProtectionVoltage limiting, recovers automatically after fault condition is removed

ENVIRONMENT

Working Temp., Humidity:-25°C~+70°C 20%~90 %RH

Storage Temp., Humidity: -40°C~+85°C 10%~95 %RH

Vibration: 10~500Hz,5G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY

Withstand Voltage:I/P-O/P:3KVAC     I/P-O/P:1.5KVAC     O/P-FG: 0.5KVAC

Isolation Resistance:I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC

STANDARD

Safety Standard:Design refer to UL60950-1,TUV EN60950-1

EMC Standard:Design refer to EN55022 CLASS B,EN61000-3-2,-3; EN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)

OTHERS

Weight:0.6Kg

Packing: 30pcs/18.5Kg/0.99CUFT

NOTE

1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation 3.Line Regulation is measured from low line to high line at rate load. 4.Load Stability is measured from 0% to 100% rated load. 5. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel  capacitor. 6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.7. Length of set up time is measured at cold first start, turning on-off the power supply very quickly may lead to increase of the set up time.

  

  