Power Supply 1.CE Approved,100% burn-in test 2.Good quality,shortest lead time,long working life,complete protection

S-35 series switching power supply 1.CE Approved.100% burn-in test 2.Competitived Price;Good Quality;Shortest Lead Time;

S-35 series single output switch power supply Competitived price and high reliability 105 Output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum wave

ModelS-35-5S-35-12S-35-15S-35-24
DC output voltage5V12V15V24V
Output voltage rang(Note:2)±2%±1%±1%±1%
Rated output current7A3A2.4A1.5A
Output current range0-7A0-3A0-2.40-1.5A
Wave and noise(Note:3)75mVp-p100mVp-p101mVp-p100mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±1%±0.5%±0.5%±0.5%
DC output power35W36W36W36W
Efficiency70%76%78%78%
Adjustale range for DC voltage +10,-5%+10%+10%+10%
Input current0.5A/115V 0.25A/230V
AC Inrush currentCold-start current 15A/115V 30A/230V
Leakage current<0.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: auto recovery
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise, hold up time200ms, 100ms, 30ms
Vibration10-500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal 1.5KVAC, Input and enclosuer 1.5 KVAC, Output and enclosuer 0.5 KVAC
Working temperature and humidity -10°c~+60°c (Refer to output derating curve) 20%~90% RH
Store temperature and humidity -20°c~+85°c, 10%~95%RH
Weight0.4Kgs
Satety standardsMeet UL 1012 requirement(Not apply for the mark)
EMC standardsMeet FCC aprt 15 J Conduction class B

Note:                                                                                                                                                                       1. The testing condition for the parameter above is: 230VAC input, rated load, 25oC 70%RH.Temperature.

2. Error. include the setting error, line stability and load stability. (Note:5)

3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.

4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.

5. Load stability test: The load is from 0% to 100%.

6. Total output canbe maximum Current, total load can not exceed the maximum output