Welcome to ECVERY
single output power supply circuit15V/4A
single output power supply circuit15V/4A
Supplier Info
[China Supplier]
Contact Person : Ms. Wu Marina
Tel : 0086-577-27878258
Fax : 0086-577-27878258
Product Detail
power supply circuit 15V/4A 1.Switch power supply witch CE 2.Competitived price,Shortest lead time 3.Sample order is availabl

power supply circuit 15V/4A,ac/dc adapter,regulated power supply

Features:

105°C output capacitor

With short-circuit and overload protection

AC Input Power

100% full-load burn-in test

High efficiency&Low Operation temperture

Installed with EMI filter,minimum wave

Model

Performance

S-60-5

S-60-12

S-60-15

S-60-24

DC Output Volta

5V

12V

15V

24V

Output voltage tolerance(Note 2)

±2%

±1%

±1%

±1%

Rated output current

12A

5A

2.8A

1.8A

Output current range

0-12A

0-5A

0-2.8A

0-1.8A

Ripple and noise(Note 3)

70mVp-p

120mVp-p

150mVp-p

150mVp-p

Inlet stability(Note 4)

±0.5%

±0.5%

±0.4%

±0.25%

Load stability(Note 5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

60W

60W

60W

60W

Efficiency

73%

76%

77%

79%

DC voltage adjustable range

+10,-5%

±10%

±10%

±10%

Input voltage range

85~264VAC/47~63Hz;120~370VDC

Input current

2A/115V 1A/230V

Surge Current

Cold Start current  30A/115V 60A/230V

Leakage Current

<3.5mA/240VAC

Overload protection

105%~150%type:PULSING HICCUP SHUTDOWN reset:Automatic recovery

over-voltage protection

115%~135%

High temperature protection

……

temperature coefficient

±0.03%°C(0~50°C)

Start-up,upper,rentention time

800ms,50ms,20ms/115VAC 300ms,50ms,80ms/230VAC

shock resistance

10~500Hz,2G 10min./1circle,time:60min.,axes 

Withstand

Input to Output Isolation:3KVAC,input shell:1.5KVAC,output shell:0.5KVAC

Insulation Resistance

Input and out shell, output and out shell:500VAC/100M Ohm

work Temperature/

humidity   

-10°C~+60°C,20%~90%RH

Storage Temperature,temperature

-20°C~+85°C,10%~95RH

Outline dimension

159*97*38mm

Weight

0.55Kgs

Safety standards

Satisfy UL1012,TUV EN60950

EMC Standard

Satisfy IEC801-2,3,4,IEC555-2

Note: 

1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH. 

  Humidity. 

2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).

3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF 

  capacitor circuit. 

4.The incoming line voltage stability test: the minimum full load voltage of the 

  incoming line to the highest voltage. 

5.Load stability test: the load from 0% to 100%.

6. C2,3,6 must Remove