Features:
DC input:40VDC-60VDCHigh Efficiency, and High reliabilityOutput protections: OCP/SCP/OVP/OPPWide operating ambient temperature (0°C~45°C)All using 105°C long life electrolytic capacitors100% full load burn-in test1 years warrantySPECIFIATON
MODEL | DDE-48D20V12 | |
OUTPUT | Output Number | V1 |
DC Output | 12.0V | |
Rated Current | 1.6A | |
Current Range Note 1 | 0~1.6A | |
Ripple and Noise Note 2 | 0~45°C | |
Voltage Accuracy | ±2.0% | |
Line Regulation | ±0.5% | |
Load Regulation | ±1.0% | |
Set-up Time | / | |
Hold up Time | / | |
Temperature Coefficient | ±0.3%/°C | |
Overshoot and Undershoot | <5.0% | |
INPUT | Voltage Range | 40VDC-60VDC |
Frequency Range | / | |
Efficiency(Typical) | 70% | |
DC Current(max.) | 0.8A | |
Inrush Current(Typical) | 25A | |
Leakage Current | / | |
PROTECTION | Over Power | 110%~180% Constant Rate Output Power |
Over Current | 110%~180% Constant Rate Output Power | |
Over Voltage | 110%~180% Shut down | |
Shorted Circuit | Long-term mode,auto recovery | |
ENVIRONMENT | Operating amb.Tem.& Hum. | 0°C~45°C; 20%~95%RH No condensing |
Storage Temp. & Hum. | -25°C~85°C; 10%~95%RH No condensing | |
SAFETY & EMC(Note 3) | Safety Standards | GB4943-2001;EN60950-1:2006 |
Withstand Voltage | Primary-Seondary:0.5KVAC;≤10mA.Primary-PG:0.5KVAC;≤10mA.Secondary-PG:0.5KVAC;≤10mA. | |
Isolation Resistance | ≥100M ohms | |
EMI Conduction & Radiation | / | |
Harmonic Current | / | |
EMS Immunity | / | |
OTHERS | MTBF(MIL-HDBK-217F) | More than 100,000Hrs(25°C,Full load) |
Dimension (L*W*H) | 143×59×38mm | |
Cooling Method | Cooling by free air convection | |
NOTE | 1.All parameter NOT specially mentioned are measured at rated input,rated load and 25°C of ambient temperature.2.Measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1µF & 10µF parallel capacitor.3.The SPS is considered a component which will be installed into final equipment.The equipment must be re-confirmed that it still meets EMC directives. |