Welcome to ECVERY
75W 5V Switching power supply S-75-5
75W 5V Switching power supply S-75-5
Supplier Info
[China Supplier]
Contact Person : Mr. Eric
Tel : 86-577-61750378
Fax : 86-577-61750377
Product Detail
led switching power supply S-75 1)5V,12V,15V,24V 2)CE,ROHS approval 3)Outline dimension:159*97*38mm 4)OEM

Switching power supply S-75-5

Model

Performance

S-75-5

S-75-12

S-75-15

S-75-24

DC output voltage

5V

12V

15V

24V

Output voltage tolerance(Note 2)

±2%

±1%

±1%

±1%

Rated output current

15A

6.3A

5A

3.2A

Output current range

0-10A

0-4.2A

0-3.4A

0-2.1A

Ripple and noise(Note 3)

70mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note 4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note 5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

75W

75.6W

75W

76.8W

Efficiency

71%

78%

78%

82%

DC voltage adjustable range

+10,-5%

±10%

±10%

±10%

Input voltage range

85~132VAC/47~63Hz;170~264VAC choose by switch 47-63Hz;240-370VDC

Input current

1.6A/115V 0.8A/230V

Surge Current

Cold-start current 18A/115V 36A/230V

Leakage Current

<0.5mA/240VAC

Overload protection

105%~150% type:pulsing hiccup shutdown Resetreset:Automatic recovery

over-voltage protection

105%~150%

High temperature protection

……

temperature coefficient

±0.03%°C(0~50°C)

Start-up,rise,hold up time

200ms,100ms,30ms

shock resistance

10~500Hz,2G 10min./1circle,Period for 60min.,Each axes  

Withstand voltage

Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,

output and enclosure:0.5KvAC

Insulation Resistance

Input and Output internal: input and enclosure,output and enclosure:

500VDC/100M Ohms

work Temperature/

humidity   

-10°C~+60°C(Refer to output derating curve),20%~90%RH

storage temperature /humidity

-20°C~+85°C,10%~95%RH

Outline dimension

159*97*38mm shell:901

Weight

0.5Kgs

Safety standards

Satisfy UL1012,TUV EN60950

EMC Standards

------------

Note: 

1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH. 

  Humidity. 

2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).

3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF 

  capacitor circuit. 

4.The incoming line voltage stability test: the minimum full load voltage of the 

  incoming line to the highest voltage. 

5.Load stability test: the load from 0% to 100%.

6.C2,3,6 must remove.

 