Model Performance | S-75-5 | S-75-12 | S-75-15 | S-75-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage tolerance(Note 2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 15A | 6.3A | 5A | 3.2A |
Output current range | 0-10A | 0-4.2A | 0-3.4A | 0-2.1A |
Ripple and noise(Note 3) | 70mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note 5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 75W | 75.6W | 75W | 76.8W |
Efficiency | 71% | 78% | 78% | 82% |
DC voltage adjustable range | +10,-5% | ±10% | ±10% | ±10% |
Input voltage range | 85~132VAC/47~63Hz;170~264VAC choose by switch 47-63Hz;240-370VDC | |||
Input current | 1.6A/115V 0.8A/230V | |||
Surge Current | Cold-start current 18A/115V 36A/230V | |||
Leakage Current | <0.5mA/240VAC | |||
Overload protection | 105%~150% type:pulsing hiccup shutdown Resetreset:Automatic recovery | |||
over-voltage protection | 105%~150% | |||
High temperature protection | …… | |||
temperature coefficient | ±0.03%°C(0~50°C) | |||
Start-up,rise,hold up time | 200ms,100ms,30ms | |||
shock resistance | 10~500Hz,2G 10min./1circle,Period for 60min.,Each axes | |||
Withstand voltage | Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC, output and enclosure:0.5KvAC | |||
Insulation Resistance | Input and Output internal: input and enclosure,output and enclosure: 500VDC/100M Ohms | |||
work Temperature/ humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | |||
storage temperature /humidity | -20°C~+85°C,10%~95%RH | |||
Outline dimension | 159*97*38mm shell:901 | |||
Weight | 0.5Kgs | |||
Safety standards | Satisfy UL1012,TUV EN60950 | |||
EMC Standards | ------------ | |||
Note: 1.The above parameters test conditions: 230VAC input, rated load, 25 °C 70% RH. Humidity. 2.Tolerance: includes set up tolerance, line stability and load stability (Note 5). 3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF capacitor circuit. 4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 5.Load stability test: the load from 0% to 100%. 6.C2,3,6 must remove. |