Model Specification | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-24 | S-100-27 | S-100-48 |
DC output voltage | 3V | 5V | 7.5V | 12V | 15V | 24V | 27V | 48V |
Output voltage error (Note2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 20A | 20A | 13.6A | 8.5A | 6.7A | 4.5A | 3.7A | 2A |
Output current rage | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-4.5A | 0-3.7A | 0-2A |
Wave and noise(Note3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability(Note5) | ±0.5% | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
DC output power | 60W | 100W | 102W | 102W | 100.5W | 108W | 99.9W | 96W |
Efficiency | 70% | 78% | 80% | 81% | 81% | 84% | 84% | 84% |
Adjustable range for DC voltage | 2.85-3.3V | 4.75-5.5V | 6.75-8.25V | 10.8-13.2V | 13.5-16.5V | 21.6-26.4V | 26-32V | 43.2-52.8V |
AC input voltage range | 85132VAC/180264VACselected by switch4763Hz;255-370VDC |
Input current | 2.4A/115V 1.2A/230V |
AC impulse current | Cold-start current 30A/115V 60A/230V |
Leakage current | <1mA/240VAC |
Overload protection | 105%150% TypePULSING HICCUP SHUTDOWN Reset: auto recovery |
Over-voltage protection | |
High-temperature protection | |
Temperature coefficient | ±0.03%(050) |
Setup rise hold up time | 200ms,100ms,30ms |
Vibration | 10500Hz,2G 10min./1cycle,Period for 60min,Each axes |
Withstand voltage | Input and output interval1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC |
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure0500VAC/100M Ohms |
Working temperature and humidity | -10+60,20%90%RH |
Store temperature and humidity | -20+85,10%95RH |
Overall dimension | 199*98*38mm |
Weight | 0.5Kgs |
Safety standards | Meet UL 1012 requirement(Not apply for the mark) |
EMC standards | Meet FCC Part 15J Conduction Class B |
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2311must be knocked down. |