Model Specification | D-120A | D-120B | ||||
CH1 | CH2 | CH1 | CH2 | |||
DC output voltage | 5V | 12V | 5V | 24V | ||
Output voltage range(Note:2) | ±2% | ±6% | ±2% | ±7% | ||
Rated output current | 12A | 5A | 10A | 3A | ||
Output current range | 2-12A | 0.5-5A | 2-10A | 0.4-3A | ||
Wave and noise(Note:3) | 60mVp-p | 120mVp-p | 60mVp-p | 150mVp-p | ||
Inlet stability(Note:4) | ±0.5% | ±1% | ±0.5% | ±1% | ||
Load stability(Note:5) | ±0.5% | ±5% | ±0.5% | ±6% | ||
DC output power | 120W | 122W | ||||
Efficiency | 78% | 80% | ||||
Adjustable range for DC voltage | CH1;+10,-5% | CH1;+10,-5% | ||||
AC input voltage range | 85~132VAC/170~264VAC selected by switch 47~63Hz,248~370VDC | |||||
Input current | 2.5A/115V 1.25A/230V | |||||
AC Inrush current | Cold-start current 30A/115V 60A/230V | |||||
Leakage current | <3.5mA/240VAC | |||||
Overload protection | 105%-150% Type: pulsing hiccup shutdown Reset: auto recovery | |||||
Over-voltage protection | CH1;5.75-6.75V | |||||
Temperature coefficient | ±0.03%/°C(0~50°C)ON+5V | |||||
Setup, rise, hold up time | 200ms,50ms,20ms | |||||
Vibration | 10~500Hz, 2G 10min,/1 cycle. Period for 60min,Each axes | |||||
Withstand voltage | Input and output internal:1.5KvAC,Input and enclosure:l.5KvAC,Output and enclosure:0.5KvA | |||||
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ | |||||
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH | |||||
Store temperature and humidity | -20°C~+85°C,10%~95%RH | |||||
Overall dimension | 199X98X38mm | |||||
Weight | 0.85kgS | |||||
Safety standards | UL1950TUVEn60590 | |||||
EMC standards | CISPR22(EN55022)class B,IEC801-2,3,4,IEC555-2Verification |
120W double outputs switching power supply