Switching Power Supply 50W
Features:Universal AC input / Full rangeProtections: Short circuit / Overload / Over voltageCooling by free air convectionLED indicator for power on100% full load burn-in testAll using 105ºC long life electrolytic capacitorsWithstand 300VAC surge input for 5 secondHigh operating temperature up to 70Withstand 5G vibration testHigh efficiency, long life and high reliability
INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 72% | 78% | 81% | 83% | 84% | 86% | |
AC CURRENT(Typ.) | 1.3A/115VAC 0.8A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 33A/230VAC | ||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70ºC (Refer to output load derating curve) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85ºC, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes |