150W LED Power Supply - 12V AC Adaptor, 12V transformer, LED transformer
High efficiency, high reliability
Switch to select the input voltage range
100% load burn-in test
Protections: Short circuit / overload / over voltage
Short circuit, overload, over voltage protection
Air cooling
2-year shelf life
Size: 199*110*50mm(L*W*H)
Application: Using for LED Strip lighting, 12V AC Adaptor
Model No. | DF-P-150-5 | DF-P-150-9 | DF-P-150-12 | DF-P-150-13.5 | DF-P-150-15 | DF-P-150-24 | DF-P-150-27 | DF-P-150-48 | |
Output | DC Output Voltage | 5V | 9V | 12V | 13.5V | 15V | 24V | 27V | 48V |
Output Capacity Tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated Output Current | 30A | 16.7A | 12.5A | 11.2A | 10A | 6.5A | 5.6A | 3.2A | |
Output Current Range | 0-30A | 0-16.7A | 0-12.5A | 0-11.2A | 0-10A | 0-6.5A | 0-5.6A | 0-3.2A | |
Output Power | 150W | 150.3W | 150W | 151.2W | 150W | 156W | 151.2W | 153.6W | |
Ripple and Noise | 150mVp-p | 180mVp-p | 180mVp-p | 180mVp-p | 180mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | |
DC voltage adjustable range | ±10% | -12%,+15% | -12%,+10% | -12%,+11% | ±10% | -12%,+16% | -12%,+11% | ±10% | |
Start, rise, hold time | 100ms,50ms,20ms Over Load | ||||||||
Input | Input Voltage Range | 88--132 VAC/176--264VAC 47--63Hz, Select from the switch 248~370VDC | |||||||
AC Input Current | less than 3.2A/115 V 1.6A/ 230 V | ||||||||
Effeciency | 78% | 80% | 82% | 83% | 84% | 85% | 86% | 87% | |
Surge Current | Cold Start Current 35A/230VAC | ||||||||
Leakage Current | less than 3.5mA/240VAC | ||||||||
Protection Feature | Overload Protection | 110%--160% | |||||||
Protection Mode: cut output, automatic recovery returned | |||||||||
Over Voltage Protecton | 115%--135% | ||||||||
Protection Mode: cut output, automatic recovery returned | |||||||||
Environment | Temperature, humidity | -25degree to +45degree; 20% to 90 %RH | |||||||
Storage temperature, humidity | -20degree to +85degree; 10% to 95 %RH | ||||||||
Earthquake resistance | 10 ~ 500Hz, 2G 10min. / 1 cycle, duration 60 minutes, each axis | ||||||||
Safety | Pressure | Between input and output: 3KVAC input and ground: 1.5KVAC output and ground: 0.5KVAC | |||||||
Insulation resistance | Input and output, the input and ground, output and ground: 100M Ohms/500VDC | ||||||||
Standard | Safety standards | UL1012, UL1950, TUV EN60950 | |||||||
EMC Standard | EN55022, EN61000-3-2, -3, EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024 | ||||||||
Others | Gross Weight | 0.8Kg | |||||||
Packing | 16pcs/13.8Kg/0.95CUFT | ||||||||
Remark | 1. All parameters are not specified, the are 230VAC input, rated load and 25 degree, the measured value.2. Ripple and noise voltage is in the 20MHz bandwidth of the oscilloscope with a 12 inch twisted pair terminal 0.1μ and 47μ capacitance increase measured.3. Set the error tolerance is the voltage, voltage regulation and current regulation of the total.4. The power to consider as a device installed in the final device, the device must be re-confirmed its EMC targets. |