1.The low price with high quality 2.CE ROHS 3.2 years quality assurance 4.LED power supply
Model | S-400-5 | S-400-12 | S-400-24 | |
Output | DC output voltage | 5V | 12V | 24V |
Output voltage tolerance | ±1% | ±1% | ±1% | |
Rated output current | 60A | 33A | 16.7A | |
Output current | 0~60A | 0~33A | 0~16.7A | |
Output power | 300W | 400W | 400W | |
Ripple and noise | 100mVp-p | 80mVp-p | 80mVp-p | |
DC adjustable range | ±10% | ±10% | ±10% | |
Setup rise hold up time | 200ms,50ms,20ms | |||
Input | Input voltage range | 85~132VAC 170~264VAC 47~63Hz, 240~370VDC | ||
AC input current | 6.5A/115V 4A/230V | |||
Efficiency | 74% | 83% | 86% | |
AC inrush current | Cold start current 25A/115V 50A/230V | |||
Leakage current | smaller than3.5mA/240VAC | |||
Protection characteristic | Over load protection | 105%~135%rated output power start the over load protection | ||
Protection mode : cut off the output,auto-recovery | ||||
Over-voltage protection | 115%-135% cut off the output,auto-recovery | |||
Over-temp protection | Rectifier≥80°Ccut off the output ,auto-recovery | |||
Fan ON/OFF control | ≥55°C Fan start ,≤45°CFan off | |||
Environment | Working temperature | -10°C~+60°C;20%~90%RH(please refer to the Load deduction curve) | ||
Security | Withstand voltage | Between input and output::1.5KVAC The input and ground : 1.5KVAC The output and ground :0.5KVAC | ||
Insulation resistance | Between input and output: The input and ground, the output and ground: 100M 0hms /500VDC | |||
Others | Weight/Packing | 1.0kg/20PCS/20kg |