Product Detail
1.Universal input voltage 2..10Years Experience Factory 3.2 years warranty 4.12V switching power supply

AC/DC DC/DC Switching Power Supply (SMPS) 35W Single Output S-35 Features: 1) AC input range selected by switch. 2) Protections: Short circuit/Over load. 3) Cooling by free air convection. 4) 100% full load burn-in. 5) Lost cost. 6) High reliability. 1. INPUT: 85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC 47 ~ 63Hz 2. SETUP, RISE, HOLD TIME: 200ms, 100ms, 30ms 3. WORKING TEMP.: -10 ~ +60 C 20 ~ 90% RH 4. WITHSTAND VOLTAGE: I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC 5. ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC 6. DIMENSION: 129*98*38mm (L*W*H) 7. PACKING: 0.4Kg; 45PCS/18.1Kg/0.57CUFT

Model  /SpecificationS-35-5S-35-12S-35-15S-35-24
DC  output  voltage5V12V15V24V
Output  voltage  error(Note2)± 2%± 1%± 1%± 1%
Rated  output  current7A3A2.4A1.5A
Output  current  rage0-7A0-3A0-2.4A0-1.5A
Wave  and  noise(Note3)75mVp-p100mVp-p100mVp-p100mVp-p
Inlet  stability(Note4)± 0.5%± 0.5%± 0.5%± 0.5%
Load  stability(Note5)± 1%± 0.5%± 0.5%± 0.5%
DC  output  power35W36W36W36W
Efficiency70%76%78%78%
Adjustable  range  for  DC  voltage± 10, -5%± 10%± 10%± 10%
AC  input  voltage  range85~132VAC/170~264VACselected  by  switch
Input  current0.85A/115V  0.45A/230V
AC  impulse  currentCold-start  current  18A/115V  36A/230V
Leakage  current< 0.5mA/240VAC
Overload  protection105%~150%  Type:   current  limiting;     Reset;   auto  recovery
Over-voltage  protection… …
High-temperature  protection… …
Temperature  coefficient± 0.03%  degrees  Celsius  (0~50  degrees  Celsius)
Setup  rise  hold  up  time200ms, 100ms, 30ms
Vibration10~500Hz, 2G  10min. /1cycle, Period  for  60min, Each  axes
Withstand  voltageInput  and  output  interval: 1.5KVAC,   Input  and  enclosure: 1.5KVAC,   Output  and  enclosure: 0.5KVAC
Isolation  resistanceInput  and  output  interval,   Input  and  enclosure,   Output  and  enclosure:   0500VAC/100M  Ohms
Working  temperature  and  humidity-10  degrees  Celsius~+60  degrees  Celsius,   20%~90%RH
Store  temperature  and  humidity-20  degrees  Celsius~+85  degrees  Celsius, 10%~95RH
Overall  dimension129*98*38mm
Weight0.4Kgs
Safety  standardsMeetUL1012
EMC  standards… …
Note:1. The  testing  condition  for  the  parameter  above  is: 230VAC  input,   rated  load, 25  degrees  Celsius  70%Rh, Humidity2. Error, include  the  setting  error,   line  stability  and  load  stability. (Note: 5)3. Wave  test: adopting“ A12” double  wire  for  20MHz, and  0.1uF& uF  capacitor  short-circuit  for  interrupting4. Inlet  voltage  stability  test:   when  is  over  load,   the  lowest  voltage  of  inlet  is  representative  to  the  highest  voltage.5. Load  stability  test:   The  load  is  from  0%  to  100%, others  60%.6. C2,   3,   11must  be  knocked  down.