Paramete | Function | Set range | Default | Note |
E1 | Timing start temperature | 0 to 100oC | 0oC | Count down time will be started only when water temperature is achieved;when it is set to 0,the function is cancelled. |
E2 | Energy-saving warm-up time | 0 to 30Min | 15Min | Count down time will be started only when it heats for 15 minutes;when it is set to 0,the function is cancelled. |
E3 | Heat insulation temperature | 0 to 100oC | 55oC | It starts heating when it is lower than heat insulation temperature |
E4 | Heat insulation hysteresis | 1 to 20 | 5oC | It stips heating when it is higher than(heat insulation temperature+Hysteresis) |
E5 | Offset on room temperature | -30 to 30oC | 0 | |
P1 | Alarm temperature | 70 to 150oC | 120oC | When water temperature exceeds the value,it will display Er1 to alarm |