Welcome to ECVERY
AT908 CD series temperature controller
AT908 CD series temperature controller
Supplier Info
[China Supplier]
Contact Person : Mr. CHEUNG JAM
Tel : 86-760-22601341
Fax : 86-760-22601873
Product Detail
AT908 CD series temperature controller 1.modular output, 2.multiple input specification available 3.PID high accuracy 4.SMPS

AT908 CD series temperature controller

Self-diagnosis function. Free 4-digit measurement value setting. Every parameter can be shielded. Various input specification are available, including thermocouple, thermal resistance and linear signal etc.. Adopting modular structure output mode. Multiple output modular specifications are available, which can adapt to different application.

Adapting intelligent PID control arithmetic without over adjust. The controller still has auto-tuning function. Be applicable with universal AC 85~256V SMPS or DC 24V power supply. Pre-setting emendation system (for input specification) inside. Freely switch between different input specifications. (various thermocouple, thermal resistance, linear signal etc..)

High accuracy and stable control effect.

Technical parameter :

   

Model

AT908-CD400

External dimension

W*H*D/(mm)

48* 96 * 90

Perforate dimension

W*H(mm)

45 * 92

Display units

Twin 4-digit LED display, range -1999~9999 (display range is free setting)

Scale and control precision

Accuracy: 0.3 grade;    Control deflection :±1 digit;  Internal measurement correction ±100yard;  Precision:  0.1°C for K .E. T. N. J. Cu50. Pt100 ; 0.001 for pressure, weight, water level

Control effect (available)

F: PID reverse adjust (for heating);  D:PID positive adjust(for refrigeration); Transmitter output

Input signals (available)

Thermo-couple: K.E.J.S.B.T.R.N;  Thermo-resistance: Pt100. Cu50 ; Linear signal: 0~20mv,0~60mv,0~100mv,0~500mv,0~5V,1~5V,0~10V,0-10mA,4-20mA etc.

Module for main output

L2, L1/L4, K1, K5, X, G, W1 (explanation refers to the following)

Module for AUX

L2, L1/L4, L5, K1, K5, X, G, W1, V12/V24/V5, S

Auxiliary output channel

Single auxiliary output channel

Alarm channel

1~2 alarm channel(s)

Alarm types

A: Lower deviation alarm   B: Higher deviation alarm 

 H: Higher limit alarm  L: Lower limit alarm  etc.

Power supply

Universal AC 85~265V (50/60Hz) SMPS or DC 24V

Power dissipation

≤5W

Work condition

Temperature :-10~50°C,Humidity ≤85% no caustic or magnetic field interference