Welcome to ECVERY
Current and Voltage Calibrator,Volt Calibrator,handheld calibrator,0.02% Accuracy
Current and Voltage Calibrator,Volt Calibrator,handheld calibrator,0.02% Accuracy
Supplier Info
[China Supplier]
Contact Person : Mr. ZHONG VINCENT
Tel : 86-592-5562446
Fax : 86-592-5562446
Product Detail
Source of voltage, current and frequency Measure of voltage, current, loop current and frequency.

Features and Benefits

Source of voltage, current and frequency. Measure of voltage, current, loop current and frequency. Manual stepping and automatic stepping and ramping.

Summary of Source and Measure Functions

Function

Measure

Source

DC V

0~30 V

0~10 V

DC mV

0~100 mV

0~100 mV

DC mA

0~24 mA

0~24 mA

Frequency

1.000Hz~99.999kHz

0.00Hz~20.000kHz

Others

24V power supply, Step, Ramp.

Specifications

Specifications are based on a one year calibration cycle and apply from +18°Cto +28 °C unless stated otherwise. All specifications assume a 10 minute warmup period.

1,DC Voltage Measurement

Range

Maximum measurement range

Resolution

Accuracy

(% of reading + Counts)

ETX-1815

ETX-2015

30V

0V~31V

0.001V

0.05+2

0.02+2

100mV

-15mV~125mV

0.01mV

0.05+2

0.02+2

-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.

Input resistance: >1MΩ.

2,DC mA Measurement

Range

Maximum measurement range

Resolution

Accuracy

(% of reading + Counts)

ETX-1815

ETX-2015

20mA

0~24mA

0.001mA

0.05+2

0.02+2

-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.

Input resistance:<100Ω.

3,Frequency Measurement

Range

Maximum measurement range

Resolution

Accuracy

(% of reading + Counts)

ETX-1815

ETX-2015

100Hz

1~99.999Hz

0.001Hz

0.02+1

0.01+1

1000Hz

100~999.99Hz

0.01Hz

10kHz

1k~9.9999kHz

0.1Hz

100kHz

10k~99.999kHz

1Hz

Sensitivity: 10Hz~10kHz,Vp-p≥1V; the rest:Vp-p≥2V.

Wave form: 5 counting points should be added to errors of other wave forms. Commercial frequency can be measured directly.

Product Accessories

1,Standard Accessories

A set of ETX-2015/ETX-1815 calibrator also includes the following items:

hard spot test leads (one set)alligator clips (one set)One 12V/1A power adaptor ETX-2015/ETX-1815 Users Manual

2,Optional Accessories

6 R03-model rechargeable batteries 1 Metal Box

Current and Voltage Calibrator,Volt Calibrator,handheld calibrator,0.02% Accuracy

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.