AHP5/50 AC/DC Voltage Withstand Test Set
AHP5/50 AC/DC Voltage Withstand Test Set
Supplier Info
[China Supplier]
Contact Person : Mr. FENG MINJIE
Tel : 86-29-88897866
Fax : 86-29-88897698
Product Detail
-Auto/Manual Mode -Main Parameters prestting -Main Parameters live display -Display test result -Full Protection

Application:

AHP5/50AC/DC Voltage Withstand Test Sets are mainly designed and produced for small and medium capacity AC power frequency withstand test, also can be used for DC voltage withstand test.

AHP5/50 AC/DC Voltage Withstand Test Sets are mainly composed of control unit and AC/DC testing transformer(HV unit) which output AC voltage or DC voltage.

AHP5/50 are fully automatic operated, with perfect monitoring and protection functions.Please refer to its feature for details.Besides main instrument, other optional can be provided in the package. Such as, Ball gap frame, filter capacitor, water resistor,discharge rod, high voltage ground rod, high voltage detector .

 

Product Features:

-Auto/Manual Operating Mode

-High Voltage, High Current, Duration for Withstand Test, Over Current Protection Setting in advance

-Live display of High Voltage(HV), High Current(HC), Low Voltage, and Low Current for AC Output. Low Current for DC Output is displayed on Digital Milliamp-Microamp meter, located on the top of silicon stack.

-Display test result after test finished.

-Over-current ,over-voltage and zero-start voltage protection, combined sound and light alarm.

-320×240 LCD

- Build-in micro-printer .

 

Technical Specifications:

Control module parameters

-Capacity:5kVA

-Input voltage:AC220V±10% 50Hz±1

-Output voltage:0-200V

-Output current:0-25A

-Timing range: 0-999S

-Ambient temperature:-20°C~50°C

-Voltage accuracy:≤1% (F.S)

-Currency accuracy:     ≤1% (F.S)

Test transformer (HV unit) parameters

-Capacity: 5kVA

-LV side voltage: 0-200V

-LV side current: 0-25A

-HV side voltage: AC 0-50kV, DC 0-70kV(negative)

-HV side current: AC 100mA

-Measuring voltage: AC 0-100V

-HV side/LV side turns ratio: 250:1 

 

Suggestion for Order

-Output Voltage and Current is two very important parameters for the test sets. Basically, Output Voltage of the instrument must more than test voltage of test object required according to relevant Codes. Output current must be more than capacitance current of test object.

-All test transformer's output is alternative current, DC obtained by silicon stack rectifying. However, silicon stack is half wave rectification. ripple factor big. If customer need DC output very often, we suggest he could use High Voltage DC withstand test sets. For example,DP801,802,803,804

-If you need very big capacity test transformer for withstand test, very-low frequency or Series Resonance Frequency should be better choice for you.

-If you have any difficult for both parameters or product choice, please contact us freely.

Order Information

-Test Transformer 1 piece

-Control Module 1 piece

- Test leads 1 set

AHP5/50 AC/DC Voltage Withstand Test Set