Hot sellin constant temperature and humidity test chamber in China
1.Implementation of standards:
a.GB10589-89Technical conditions of high and low temperature test chamber
b.Meet the standard:
GB2423.1-89 Low-temperature test methods;GB2423.2-89 Test Method for High Temperature;IEC68-2-30 Test methods;2.Application:
The electrical, electronics, household appliances, automobiles, motorcycles, chemicals and other products from parts and materials for low-temperature test.
3.Feature Specification:
1. Model:Auto/J-20 Auto/J-40 Auto/J-60
2.All imports of stainless steel shell, beautiful appearance
3.Import of refrigeration units, the main parts are imported international brands, the whole system is equipped with multiple protection devices, to improve reliability.
4.clever duct structure, small temperature deviation
5.Door with observation window, the test specimen can be easily observed state
6.Operation of the system is very simple, very easy installation and maintenance
4.Technical parameters:
Model | High and low termpture test chamber | ||||||
AUTO/J-20 AUTO/J-40 AUTO/J-60 | |||||||
Feature | Temperature Method | PID intelligent adjustment | |||||
Temperature range | -20°C-+130°C(150°C) ;-40°C-+130°C(150°C) ;-60°C-+130°C(150°C) | ||||||
Temperature uniformity | ± 1.5°C | ||||||
Temperature fluctuations | ±0.5°C | ||||||
Heating time | -20°C-+130°C in 70 minutes, -40°C-+130°C in 80 minutes, -60°C-+130°C in 80 minuts | ||||||
Cooling time | +20°C--20°C°Cin 40 minutes,+20°C---40°C in 60 minutes, +20°C--60°C in 70 minutes | ||||||
Inside volume(L) | 100 | 150 | 225 | 408 | 800 | 1000 | |
Stadio size(mm) | 400X500X500 | 500X600X500 | 500X600X750 | 600X800X850 | 800X1000X1050 | 1000X1000X1000 | |
Weight(kg) | 200 | 250 | 300 | 400 | 600 | 700 | |
Material | The inside of material | SUS304 bright stainless steel thickness = 1.2-1.5mm | |||||
outer covering material | SUS304 brushed stainless steel cold-rolled steel plate or anti-rust treatment (spray ) | ||||||
Insulation Heat | fine glass wool or polyurethane foam | ||||||
Refrigerator sytem | Cooling method | single-stage mechanical refrigeration means two yuan mechanical refrigeration means | |||||
Refrigerator | closed (import) compressor | ||||||
Refrigerator | R22 R404 R502 | ||||||
Condensation method | air-cooled or water cooled | ||||||
Heater | Nichrome heating wire heater | ||||||
Inlet system | axial fan | ||||||
Airflow Method | broadband type forced air circulation (on the next entry) | ||||||
Control system | programmable touch screen thermostat Korea DZX5000 | ||||||
TEMP850 Control system | import digital temperature controller (FY900 Korea) programmable touch screen thermostat Korea TEMP850 | ||||||
Standard configuration | observation window (double-layer hollow glass) a test hole diameter of 60mm (at left) 1, layer 2 sample holder, box lights (Firefly Lights) 1,1 water tank, small casters 4, a power cord | ||||||
Safety device | sample over-temperature protection, leakage protection, overload the fan, compressor over-voltage, overload, overcurrent protection, phase sequence protection, fuse. |