1.CO translates into CO2 device(only domestic owns) 2.Sensibility (Min. reading): 0.1ppm 3.Double carbon and sulfur ponds

Main technical parameters

Analysis theory:high-frequency furnace burn infrared absorptive detection.

Range of measurement: C:0.00001%-10.0000% (can extend to 99.99999%)  

                                           S:0.00001%-6.0000% (can extend to 99.99999%)

Analytical error:accord with GB/T20123-2006/ISO15350:2000 standard

Analysis precision:C:RSD≤0.5 %      S:RSD≤1.0%

Sensibility (Min. reading):0.1ppm

Detection pond: C:C Pond (can add low C pond )  

                             S:S Pond ( can add High S pond )

Time of analysis:20-100s can setting(usually 35s)

High-frequency furnace:power ≥2.7KVA  Oscillation frequency:20MHz

Electronic balance:weight the sample in variable amount   Accuracy of reading:0.0001g

Work environment: indoor temperature:10-30°C,relative   humidity:<75%,voltage:AC220V±5%,frequency:50Hz±2%

The key characteristics

The instrument imports the advanced technology from abroad, is a high-tech product with integration of light, machine, electricity, sensors, computers and analysis technology etc. Measurement range is extensive, antijamming capability is powerful, all-ready function, easy to operate, the analysis result is exact and reliable etc. Most components of the instrument are imported from abroad, and the machine is comparable with imported products. 

1. Humanized circular arc and stainless steel table-board design, easy to operate.

2. Domestic pioneering double carbon and double sulfur pool access to analysis the ultra low and higher content, and automatic switching.

3. High-speed sampling 24 realizes the dynamic data integral of analysis procedure; improve the analysis sensitivity and accuracy rating.

4. CO translates into CO2 device(only domestic owns), improves the degree of accuracy of measuring the C.

5. Use7.5KVA high-frequency ceramic power tube, burn the samples adequately and its stability is good.

 

6. Snap-in type automatic sweep technique ( with patent ) and ultramicropore mental dust filter,reducing the influence of dust to analysis result, easy to dismantle, be in favor of maintain.

7. Low tension heating ring ( with patent technology) heating in furnace end, which can improve the percent conversion and stabilize the analysis result of S.

8. Infrared detection part and high-frequency furnace are connected by optical (domestic pioneering),coordinate with multilevel covert style isolation circuit,which can avoid the high-frequency interference thoroughly.

9. Dedusting and decontamination plant adopt internal pressure seal, tightness and purification effect is good, easy to replace.

10. WINDOWS Xp English operating interface, the analysis software adopts Deliph software compiling, function setup is powerful, and the interface is distinct and visualized.

11. Powerful data statistics function, networking operation, data transmission on the internet and number off.

Allocation

High -frequency Reaction combustion furnace

1. Output power of the high-frequency furnace 2.7KVA; frequency 20MHz.

2. Automatic leak hunting, overtime, overcurrent warning.

3. Current / voltage / power / choice ways to adjust the furnace temperature is suited to samples in different materials.

4. High-precision flow controller can guarantee the stability of the air current.

5. Ultramicropore mental dust filter- 0.4mu, can insure the completely separation between the dust and gas.

6. Low tension heating and constant temperature in furnace end,can improve the percent conversion of S, and stabilize the analysis result of S.

7. Snap-in type burner can clean automatically,reducing the influence of dust to analysis result.

8. High-pressure ash discharge system,can sweep away the dust in the pipeline thoroughly.

Infrared Carbon & Sulfur Analyzer 

1. Circuit:The circuit adopts double CPU system, upper and low computer are modular design, low computer uses Atmega162 as control singlechip, the electronic circuit integration degree is high, steady and reliable.

2. Sampling:Adopts high-speed 24 ADS124 sampling chip, fast speed and high precision.

3. Communication:Upper and low computer adopt USB2.0 interface, improve the communication speed greatly.

4. Connection:Infrared detection part and high-frequency furnace are connected by optical (domestic pioneer),coordinate with multilevel covert style isolation circuit,which can avoid the high-frequency interference thoroughly.

5. Power supply:Industrial integration linear module power supply, stable output and trouble-free.

6. Light source:Tailor-made new platinum infrared light source, fever continued, and high efficiency of the spectral characteristics.

7. Analysis pond:Gilded C&S analysis pond and high-precision pyroelectricity infrared detector.

8.Electrical machine:Aviation dedicated synchronous machine,well thermostability,can continue use 100 thousand hours.

9. CO translate into CO2 device(only domestic owns),improves the degree of accurancy of C.

Analysis Software

1. Operational software: Adopt Deliph software compiler, and WINDOWS Xp English operating software.

 

2. Analysis channel:Provide channel management function,C&S channel can add, delete and edit by itself, no quantitative restriction, preset low carbon and high-sulfur interface,realize the automatic switchover of software.

 

3. Analysis functions: Analysis procedure dynamic data integral, sampling 24 times/s, improve the sensitivity and accuracy rating of analysis, manage the sample, including edit the name, logo of samples, increase and delete sample name. The software provides multi-user management system, the manager can sset up different user rights. 

4. Show function: C and S hold a curve box respectively; show the real-time data and C & S release curve in the analysis process dynamically.

5. Print function: multiple print mode, the two print modes-laboratory and check station are provided, and it can plan print format by itself.

 

6. Self diagnosis function: System diagnosis, detecting sealing of the furnace head and gas chamber by software. 

CS-8800C Type High-frequency Infrared Carbon Sulfur Analysis Instrument

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.