Hydrostatic tester is used for hydrostatic testing of pipes and checking if there is leekage defect in the pipes. Thus the merchanical properties can be assured.
Technical Performance and Requirements:
1. Size and end position of tested pipes:
Outside diameter: Φ508mm~Φ2540mm;
Wall thickness: 8~25mm;
Length: 8~15m;
End position: After cutting by plasma, the beginning and ending point of the axial deviation of
cutting≤3mm.
2. The maximun weight of a single pipe: 23t.
3. Pipe material: The highest grade steel X70 API Spec 5L(44 version of line pipe
specification)
The implamentition standard of pipes: API Spec 5L(44 version), GB/T9711.1-1997,
GB/T9711.2-1997, SY/T5037-2000, SY/T5040-
2000.
4. Maximun testing pressure: 25MPa.
5. Sealing type: End sealing.
6. Regulator time: 5~15s(The max is 30s. The regulator time can be regulated.)
7. When stable, the range of pressure fluctuations: 0~0.3MPa.
8. Maximun bearing capacity of hydrostatic tester: 2800t.
9. Production capacity: 6(Φ1422mm)~15(Φ508mm) roots/h.
2800t Hydrostatic Tester