Programmable DC Electronic Load 0~120V/1mA~30A/300W Remote measurement function Standard RS232C interface

Function:

CC mode

In the mode of CC, electronic load analogs as a constant load, the current won’t change as voltage when the current is within the input range

For reducing the current setup critical shock, the rise time can be set, load controls the current to rise

In the process of CC, switch to short working status directly, load controls the Max.current to

Test the short input of power and protection ability.

CV mode

In the mode of CV, electronic load analogs as a constant load, the voltage won’t change as current when the current is within the input range

For reducing the voltage shock, the rise time can be set, load controls the voltage to rise

In the process of CV, switch to short working status directly, load controls the Min.voltage to

Test the short input of power and protection ability.

CP mode

In the mode of current power, within the power input ability range, electronic load consumes a constant power, generally, analog in terms of constant current, load current is adjusted dynamically with voltage.

In the mode of CP, load consumes a constant power. When the input voltage changes, load will adjust current to maintain the consumed power.

CR mode

In the mode of constant resistance, load works in terms of CC or CV, the load current or voltage can be adjusted dynamically according to the change of input power, so that load equals to a constant resistance.

In the mode of CR, load equals to a constant resistance, load will consume the current changed as voltage

Battery measurement mode

The discharge test works in terms of CC or CR, and test automatically in same mode or different modes according to the set switch time to analog the working status of battery; in the process of lasting discharge, the battery voltage drops constantly, when load input voltage is lower than the set value, the discharge test stops automatically, and the tester can display the discharge time and the capacitance of battery.

Auto list measurement mode

   List test function can realize the different loads to switch automatically based on the set time.

   As for the power and discharge device, the working feature of tested product in different application can be got deeply and widely by multi parameter fixed test.

SPECIFICATIONS

Rated valueInput voltage0~120V
input current1mA~30A
input power300W
 rangeaccuracyresolution
acy Load accur0-9.999V±(0.1%+0.03%FS)1mV
10V-99.99V±(0.1%+0.03%FS)10 mV
100V-120V/360V±(0.1%+0.03%FS)100mV
0-9.999A±(0.1%+0.2%FS)1mA
0-15A/30A±(0.2%+0.5%FS)10 mA
CV mode1.5V-18V/36V±(0.1%+0.03%FS)1mV
1.5V-120V/360V±(0.1%+0.03%FS)10 mV
CC mode0-3A±(0.1%+0.2%FS)1mA
0-15A/30A±(0.2%+0.5%FS)10mA
CR mode0.1Ω-10Ω±(1%+0.3%FS)0.001Ω
10Ω-99Ω±(1%+0.3%FS)0.01Ω
100Ω-999Ω±(1%+0.3%FS)0.1Ω
1KΩ-4KΩ±(1%+0.8%FS)
CP mode0-10W±(1%+0.1%FS)1 mW
10-100W±(1%+0.1%FS)1 0mW
100-300W±(1%+0.1%FS)0.1 W
Battery test functionnInput:0.8-120V         Max measurement capacity:999A/H
Resolution:10 mA         Timer range:1~60000sec
Dynamic test modeRange of Frequency 0.1Hz-1KHz
Llist test modeRated Voltage, Rated Current, Rated Power
Rated Riesistance, SHORT, OPEN
Protection modeOver-voltage,over-current,over-power,over-temperature,opposite polarity
Power requirement198-242VAC   99V-121VAC 47.5-63Hz