RK2511 DC Low Resistance Tester
RK2511 DC Low Resistance Tester
Supplier Info
[China Supplier]
Contact Person : Ms. Li Kaixuan
Tel : 86-755-83324500
Fax : 86-755-82736668
Product Detail
RK2511 DC Low Resistance Tester,Range of testing:10u ohm-1.999k ohm,five parts;Measuring Current:0.01mA-100mA


RK2511 DC Low Resistance Tester is an instrument which designed for measuring low DC resistance. It can be widely used to measure the resistance of a variety of coils, the resistance of the motor winding resistance transformer, all kinds of cable wire, the resistance of switches plugs, sockets and other electrical components.

This instrument is used microprocessor technology to overcome the effects of DC drift, and improve measurement accuracy.

This instrument is used the method of five ports measurement to eliminate the effects of the contact resistance and the test cable lead resistance effectively.


2.1  4 1/2 LED display,The maximum resolution is 10µΩ.

2.2  Range of testing:10µΩ~1.999KΩ ,five parts

    Range 1,  200 mΩ:10µΩ~199.99 mΩ

    Range 2,  2Ω: 100µΩ~1.9999 Ω

    Range 3,  20Ω:1mΩ~19.999 Ω

    Range 4,  200Ω:  10mΩ~199.99 Ω

    Range 5,  2kΩ:   100mΩ~1.9999 kΩ

2.3 Measurement error:

Measurement error= Working error + Temperature coefficient error

2.3.1 Working error

       When the temperature is 20±5C,it is ±0.2%reading±0.01%range.

2.3.2 Temperature coefficient error

       When the temperature is 0C~15Cor25C~40C,it is (±0.002%reading ±0.002%range)/ C.

2.4 Measuring Current:

    Range 1:about 100mA

    Range 2:about 10mA

Range 3:about 1mA

    Range 4:about 0.1mA

    Range 5:about 0.01mA

2.5 Pre-heat time: 15 minutes

2.6 Measurement speed: 8 times / sec

2.7 Sorting Function:   This function just can be used when the range is locked.

   High limit setting:Set the high limit value.

   Low limit setting:Set the low limit value.

   HIGH sorting and alarm:When measure value>high limit value,Indicator (HIGH) will bright.

LOW sorting and alarm:When measure value>Low limit value,Indicator (LOW) will bright.

PASS sorting and alarm :When the measure value is between the low and high limit value,Indicator (PASS) will bright.

Buzzer:It will ring when the  PASS Indicator is bright. It can be control by the Ring key on the panel.  