Ambient Conditions
1 Ambient temperature -25°C~+70°C;
2 Relative humidity ≤90% at 40°C;
3 Atmospheric pressure 860~1060mbar(650~800mmHg approximately);
3. Insulation Rating: Class F (155°C).
4. Safety Characteristics
1 Dielectric resistance >1000MΩ in normal condition;
2 Insulation withstand voltages 3750V (50Hz)/1 min;
3Insulation impact strength Continuously 20 times impact of 6kV (50Hz)/50μS;
4 Fire retardancy In conformity with UL94-Vo;
5. Safety approval,
6. Rated Power
2VA
7. Rated Voltage
1 Standard series,
Primary 220V±25% 50Hz/60 Hz
Secondary,
single output 6V, 7.5V, 9V, 12V, 15V, 18V, 21V, 24V, 27V
double output 2×6V, 2×7.5V, 2×9V, 2×12V, 2×15V, 2×18V, 2×21V, 2×24V, 2×27V
2Non-standard series It can be customized based on customer's requirements.
8. Universal Technical Parameters of S Series Standard Product
No. | Model | Power | Idle Current | Idle Loss | Voltage Regulation Ratio | Temperature Rise | Weight (g) | Dimension L×W×H (mm)3 |
14 | S2S | 2VA | ≤12mA | ≤0.25W | ≤21% | ≤15°C | 135g | 32.6×27.6×31.25 |
( function(){ var aBigImageSrc = [ 'http://i01.i.aliimg.com/photo/v3/203074695_1/S2S_F2_Power_transformers_bingzi.jpg' , 'http://i01.i.aliimg.com/photo/v3/203074695_2/S2S_F2_Power_transformers_bingzi.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); S2S-F2 Power transformers bingzi